  187   Thu Apr 19 15:18:25 2007 Doug PreddyStart Uppreparing to start the refrigeratorStarting the vacuum systems in the coldbox
and solenoid.
  
  183   Wed Nov 15 17:05:49 2006 Willy AnderssonQuench Recoverypowerleads cold, energizing solenoidPowerlead temperatures have bottomed out,
energizing solenoid to 300 
amps, ramp rate 60.
  
  48   Fri Sep 3 01:28:43 2004 Doug PreddyQuench Recoverypower upstarted flow to the power leads at 11:30.
Cold and stable at 1:00am. 
Energized solenoid at 1:30.
  
  114   Tue Nov 15 07:25:10 2005 Doug PreddyNormal Runningpower supply problemSaturday November 12 the solenoid power supply
ramped itself down to zero. 
It would not ramp up unless the ramp rate
  
  74   Tue Oct 26 09:45:24 2004 Doug PreddyNormal Runningpower leads warmingFlow to power leads dropped to <80 mm. Cycled
HIC142. Temps dropping, flows 
>250.
  
  123   Tue May 30 14:36:41 2006 Doug PreddyNormal Runningpower leads warmingpower leads warming. closed HIC 142, then
re-opened. temps falling
  
  248   Mon Apr 28 09:03:22 2008 Doug PreddyNormal Runningpower leads warmed during weekendThe power lead temperatures suddenly rose
on Sunday morning. No rippling occured before
the woarm up. 
I shut flow off this morning
  
  57   Sat Oct 9 22:50:26 2004 Other power leads warmedAt 10:30 PM Saturday, Donald Arseneau sees
power leads at
25K, having gone up for the previous 10 hours.
  
  21   Tue May 4 11:20:57 2004 Doug PreddyNormal Runningpower leads going unstablepower lead ripples increased over last couple
of days. They are quickly 
dieing out now and the temps are startint
  
  150   Sat Jul 29 09:38:06 2006 Doug PreddyQuench Recoverypower leads cooledopened power lead flow about 40 minutes ago.
~12K will let them stablize. 
LHE level >20%
  
  25   Wed May 5 12:13:51 2004 Doug PreddyNormal Runningpower leads coldshould be ready to run.   
  18   Wed Apr 28 09:30:09 2004 Doug PreddyNormal Runningpower leads againSame story as yesterday. Ripples dieing out,
flows down to <200 mm, temps 
increasing. Turned HIC 142 down to 0.4 then
  
  22   Tue May 4 11:26:38 2004 Doug PreddyNormal Runningpower leads Power cycled HIC 142 with solenoid power at
400 amps. Flows > 240mm and 
temps have dropped.
 may4_1053.BMP 
  58   Sun Oct 10 17:36:35 2004 ExperimentorStart Uppower leadsAt 5:30 pm sundat, power lead temp is about
10.6K.  script tool still 
notworking
  
  254   Sat Jul 26 01:29:21 2008 Doug PreddyQuench Recoverypower leadsops will monitor liquid level. When it's at
60% they will come down and open the power
lead valve. When the temperature ripples
  
  269   Wed May 27 15:01:34 2009 Doug PreddyQuench Recoverypower leadsPower leads are cold. There is still a
small ripple. The power supply can be ramped
up as soon as the ripples die out.
  
  132   Mon Jul 3 23:01:34 2006 Doug PreddyQuench Recoverypower lead warming/ripples caused quenchpower lead warming/ripples caused quench at
18:45 today. Compressor stayed 
on, but flow to solenoid stopped.
  
  240   Tue Nov 27 21:02:08 2007 Doug PreddyNormal Runningpower lead ripplespower leads were oscillating tonight. John
K. came down and cycled CV142. 
(Thanks John!) Temps settling out.
  
  45   Wed Aug 25 12:52:53 2004 Doug PreddyNormal Runningpower lead rippleLhe ripple has started. 10.9-11.4K PL-Pos
also has a smaller ripple. Both 
flows down to 230mm. Cycled HIC 142 and the
  
  89   Thu Dec 2 10:51:16 2004 Doug PreddyNormal Runningpower lead rippleRipples got worse overnight.LHe in 10.3-11.7,
PL Neg 8.0-8.7. Flows <200mm.
cycled CV142. Flows 240mm. LHe in 10.3-11.3
  