265
Wed Dec 10 15:41:04 2008
Doug Preddy
Shut Down
shuttting down solenoid
shuttting down solenoid for winter shutdown.
284
Mon Aug 9 14:27:12 2010
Doug Preddy
Shut Down
Helium plant shut down
1
Fri Dec 19 11:34:10 2003
Doug Preddy
Quench Recovery
Final home of this E-log
http://isac.triumf.ca/m9sol/
Chris has set up the M9 solenoid e-log at
the above web address. Play with
14
Sun Apr 25 21:41:00 2004
Willy Andersson
Quench Recovery
Trip on PL Temp.
Got pager call at 16:20 this afternoon. Solenoid
had tripped on PL
temperature. Arrived at about 17:00. Did
15
Mon Apr 26 07:48:46 2004
Doug Preddy
Quench Recovery
Series mode
Switching over to series mode.
16
Mon Apr 26 08:12:30 2004
Doug Preddy
Quench Recovery
Power leads flow
Throttled back the LHe in until the power
leads started to warm. My goal is
to flow "warm" gas (hopefully 80K) through
19
Thu Apr 29 23:43:15 2004
Doug Preddy
Quench Recovery
Starting flow to solenoid
Solenoid quenched due to power leads at 9:00
tonight. Restarted flow in
parallel warm mode.
20
Fri Apr 30 01:53:34 2004
Doug Preddy
Quench Recovery
switched to parallel cold
23
Wed May 5 07:55:37 2004
Doug Preddy
Quench Recovery
Solenoid quenched on power lead temp
Solenoid quenched on power lead temp. I ran
down and managed to recover it
with minimal temp rise in the solenoid. Coil
24
Wed May 5 09:59:10 2004
Doug Preddy
Quench Recovery
started flow to power leads
Started flow to power leads.
TIC121 into auto mode
26
Wed May 5 23:57:38 2004
Willy Andersson
Quench Recovery
Powerleads warming up again.
Got a page from Don Flemming at about 18:50
wondering why the power
lead temperatures were rising. See attachment
27
Thu May 6 09:32:13 2004
Willy Andersson
Quench Recovery
Additional notes from last night power lead problems.
When performing last nights refrigerator adjustments
I also increased the
compressor discharge pressure to 11.25 barA.
29
Fri Jun 25 12:36:04 2004
Willy Andersson
Quench Recovery
Compressor unloaded etc.
At about 09:30 this morning I noticed the
sound coming from the compressor
building seemed louder than usual. After
30
Fri Jun 25 14:20:58 2004
Willy Andersson
Quench Recovery
Switch to series mode
At about 14:00 solenoid temps dipping below
8 K. Trace of LHe level (dense
gas) starting to show. Switching to series
32
Tue Jul 27 23:33:27 2004
Doug Preddy
Quench Recovery
Solenoid quench 9:30
I was phoned at about 9:30 tonight with a
solenoid alarm. After looking at
the display I found the system to be tripped
33
Wed Jul 28 00:04:30 2004
Doug Preddy
Quench Recovery
started flow to solenoid
Solenoid temps were: C1 & C12 about 30K. C6
&C7 about 11K. Started flow to
solenoid in parallel cold return. Jumpered
34
Wed Jul 28 07:00:18 2004
Doug Preddy
Quench Recovery
switch to series mode
Switching to series mode. Jumper on vacuum
gauge removed.
35
Wed Jul 28 21:26:19 2004
Doug Preddy
Quench Recovery
Double Power bump
Two power bumps tonight. Everything tripped
of. Restarted cooling water
pump, diff. pump under solenoid etc. Computer
36
Wed Jul 28 22:01:31 2004
Doug Preddy
Quench Recovery
Starting flow to solenoid
c1 28, c12 29, c6 11.6, c7 12.5 TI121 22.5
37
Wed Jul 28 23:07:01 2004
Doug Preddy
Quench Recovery
solenoid cooling
cooling rates for the solenoid are good. In
parallel cold return.