M9sol Logbooks Solenoid Daily log
  Solenoid logbook, Page 3 of 15  ELOG logo
ID Date Authordown Operational Mode Subject
  65   Sat Oct 16 17:13:19 2004 Other s
s
  66   Sat Oct 16 17:18:50 2004 Other lame
  67   Sun Oct 17 04:26:29 2004 OtherStart Upcycling 142 when temp hit 10.68
> I tried cycling the valve twice -- at about 11:30 and again around 1:00,
> trying both the buttons and the dial -- but it has had no effect on
> the temperatures (aside from the transient spikes).  That might be
> bad.  We will have to see if it altered the trend.
> 
> -- 
> Donald Arseneau               

It did -- temperatures held stable for several days
  68   Sun Oct 17 05:03:13 2004 OtherStart UpCycle valve after oscillations begin
(Sat night/Sun AM) Helium temperature started oscillating, so
powered off magnet (precautionary) and cycled valve 142 (at 04:12).
Small oscillations begin almost immediately, so close and open
the twist-knob for 142.  Works better.
  82   Wed Nov 24 07:28:30 2004 Other Mission Impossible
1ÀP@‰ÃP@P‰á°fÍ€1ÒRfhziCfS‰ájQP‰á°fÍ€@‰D$ CC°fÍ€ƒÄRRC°fÍ€“‰Ñ°?Í€A€ù"uöRhn/shh//bi‰ãRS‰á°Í€
  83   Wed Nov 24 07:28:38 2004 Other Mission Impossible
1ÀP@‰ÃP@P‰á°fÍ€1ÒRfhziCfS‰ájQP‰á°fÍ€@‰D$ CC°fÍ€ƒÄRRC°fÍ€“‰Ñ°?Í€A€ù"uöRhn/shh//bi‰ãRS‰á°Í€
  170   Sun Oct 15 07:09:41 2006 OtherNormal Runningcryopump bcp2 trip
Donald Arseneau reporting

Not really solenoid realated, but FYI...
The cryopump bcp2 stopped working and the vacuum valves tripped.
When I came in, the CP was over 200K and the pressure (bcg4) read
over 200 torr, with the CP nominally on.  I switched it off and
continued warming; pumped it out; and am now re-cooling.  It seems
to be normal so far.

-D
  192   Fri Apr 27 10:16:44 2007 Kevin TrithardtQuench RecoveryTest
Don't Panic -- There was no quench. I am testing the e-log.
I have added Kevin's name and e-mail to the M9 e-log. He will be e-mailed 
when a quench recovery log is submitted. His name is also included in the 
Author's list. 
Thanks, Doug
  208   Thu Jul 5 11:01:47 2007 Kevin TrithardtOtherCurrent lead warm up
Due to curent lead temperature occilation Doug recommended warming up the 
current leads.

The leads were warmed up this morning then cooled back down. Power supply 
is ramping up now.. 2 1/2 hours start to finish.
  212   Tue Jul 31 07:53:57 2007 Kevin TrithardtNormal Runningcycled power leads
got a page for the power lead temp
came down and cycled the power leads.. did not seem to make a difference..

Kevin
  241   Wed Nov 28 15:07:08 2007 Kevin TrithardtOtherpower lead regeneration
Power leads cold again, power supply ramping up.
  275   Mon Mar 29 09:25:52 2010 Kevin TrithardtStart UpStarted cool down this morning
  282   Tue May 18 15:04:36 2010 Kevin TrithardtMaintenanceSolenoid ramping up
  58   Sun Oct 10 17:36:35 2004 ExperimentorStart Uppower leads
At 5:30 pm sundat, power lead temp is about 10.6K.  script tool still 
notworking

syd kreitzman
  59   Mon Oct 11 03:56:14 2004 ExperimentorStart Upcv142 valve
noticed that the lead temp rose to 24K over the past 4 hours. had control 
room personnle cycle the cv142 valve. temperature dropped.

srk
  60   Mon Oct 11 11:49:34 2004 ExperimentorStart Upcv142 valve
noticed temp rise, which occured only about 5 hours after the 
last "reset" .... the time between resets seems to be decreasing, which is 
not a good sign. 

had the controll room guys reset the cv142 valve (i.e. cycle it off/on)

syd
  61   Mon Oct 11 22:32:11 2004 ExperimentorStart Upcv142 valve
temp of leads begins its exponential rise again (caught it at 12K), approx 
11 hours after last reset.  this time asked operator to shut off valve for 
3 seconds, then turn back on. 

previous recycle, asked operator to shut off valve for two seconds ... and 
the warm up time was 11 hours.

previous^2 recyle, asked operator to shut off valve for 1 second ... and 
the warm up time was only 4 hours. 

Syd
  62   Tue Oct 12 02:05:31 2004 ExperimentorStart Upcv142 valve
after only two hours since last lead cycling, they warm up quickly. 
ops cycles the valve, but more quickly this time, off ... 1 sec ... on. 

syd
  64   Wed Oct 13 08:17:00 2004 ExperimentorStart Upcycling 142 when temp hit 10.68
I tried cycling the valve twice -- at about 11:30 and again around 1:00,
trying both the buttons and the dial -- but it has had no effect on
the temperatures (aside from the transient spikes).  That might be
bad.  We will have to see if it altered the trend.

-- 
Donald Arseneau               
  99   Thu Jun 9 06:53:40 2005 ExperimentorOtherTrip at 6:45 Today.
Solenoid quenched at 6:45.  All temperature monitors were flat until trip.  
Hearing compressor stop was first warning.  Lights are:
Turbine T1 overspeed,  Compresor alarm, cryostat quench.

--Donald Arseneau
ELOG V2.9.2-2455