ID Date Author Operational Mode Subject
  246   Wed Apr 16 16:51:16 2008 Doug PreddyStart Upswitched to parallel cold return
  245   Wed Apr 16 15:15:44 2008 Doug PreddyStart Uprefrigerator started
Turned on compressor last Tuesday. Ran purifier until today. Final value 0.15ppm. Started cool down yesterday. Switched into parallel cold return this morning, but PIC 229 would not allow the compressor to charge. The compressor tripped due to bad solenoid vacuum (solenoid was warming up). The controller now seems to be working okay. Restarted in parallel warm mode at ~12:00
  244   Wed Apr 16 15:12:01 2008 Doug PreddyNormal Runninggraphs to load
There are three strip tools saved: coils powerlead startup
  243   Tue Apr 1 15:17:06 2008 Doug PreddyStart UpStarting up vacuum systems
Monday afternoon there was no control of the vacuum system. The controls were working, but no output to devices. The "output" breaker in the PLC box was found to be tripped. Reseting it allowed control to the vacuum systems. I started the regeneration of BCP2 this morning, but hte output breaker tripped again. reset it and continued to pump. Started to pump out the solenoid also. Removed jumper on the BDP2 temperature read-back, bypassed BV2, and BCG2. This allows pumping through the diffussion pump. Cold box has been pumping for a few weeks. It's at 2.0 x 10-3
  242   Mon Dec 3 14:59:58 2007 Doug PreddyQuench RecoveryNot really a quench recovery, But...
Not really a quench recovery, but...I wanted to send this out via e-mail. 
The contactor for the compressor building fan failed recently. Randy is 
looking after it, but parts will have to be ordered. The big door should 
stay open until the fan is running again. 
Other than the fan, the rest of the system weathered the weather okay. 
It's up and running until Wednesday morning. After maintenance day, we 
should ramp down the solenoid power supply and leave the refrigerator 
running. We can do some training and maintenance at this time. I would 
also like to keep it cold until blocks can be removed so we can pump out 
the cold box.
  241   Wed Nov 28 15:07:08 2007 Kevin TrithardtOtherpower lead regeneration
Power leads cold again, power supply ramping up.
  240   Tue Nov 27 21:02:08 2007 Doug PreddyNormal Runningpower lead ripples
power leads were oscillating tonight. John K. came down and cycled CV142. 
(Thanks John!) Temps settling out.
  239   Mon Nov 26 09:45:43 2007 Doug PreddyNormal Runningpower lead problems
Power lead temperatures were rippling yesterday afternoon. I asked one of 
the operators to cycle CV142.
The temperatures were rippling again this morning, so I cycled CV142.
  238   Fri Nov 23 08:41:45 2007 Doug PreddyNormal Runningscreen grab of powerlead temps
  237   Fri Nov 23 08:35:37 2007 Doug PreddyNormal Runningpower lead problems
About 10 hours ago the power lead temperatures started to fluctuate and 
climb.
I cycled CV142 and the Temps have dropped and stablized.
  236   Mon Nov 19 04:30:47 2007 Doug PreddyQuench Recoveryswitched to series mode
  235   Mon Nov 19 02:58:44 2007 Doug PreddyQuench RecoverySolenoid quenched on power lead over temperature
I received a page at 1:30 this morning. The power lead temperatures were 
climbing. Cycling CV142 did not fix the problem. The solenoid quenched at 
1:50.
Restarted flow at 2:45 in parallel cold return.
  234   Fri Nov 9 18:56:20 2007 Doug PreddyMaintenanceSystem Ready to Run
M9BMP2 was replaced. Vacuum good. Solenoid is ramped up. :)
  233   Fri Nov 9 16:24:33 2007 Doug PreddyMaintenance2APLC Died
thumb wheel panel all lite up. 2APLC rebooted by Klara (Thanks). M9BMP2 not 
pumping properly. Edi is looking at it. 
  232   Fri Nov 9 14:50:03 2007 Doug PreddyQuench RecoverySolenoid cold
Solenoid cold. Added two bottles of helium. Allowing to stablize. Will 
ramp power supply in half an hour.
  231   Fri Nov 9 07:37:44 2007 Doug PreddyQuench Recoveryswitched to series mode
switched to series mode.
  230   Thu Nov 8 09:28:53 2007 Doug PreddyQuench Recoverystarted compressor
And started flow to coldbox,solenoid in parallel warm return.


Tuesday evening theree was a 2 hour power outage 19:00- 21:00. No call 
made to M9 operator.
Wednesday tried to recover vacuum. Started cool down Thursday morning.
  229   Wed Oct 24 12:04:06 2007 Doug PreddyMaintenancepower lead and cryopump regeneration
Regenerating M9B:CP2 as temperature was up to almost 20k.
Shut off flow to power leads to allow them to warm up. The positive and 
negative temps were beginning to creep up.
Regeneraing the adsorber.
  228   Tue Oct 9 13:16:44 2007 Doug PreddyQuench Recoveryswitched to series mode
  227   Tue Oct 9 12:58:22 2007 Doug PreddyQuench RecoverySolenoid Quench 2
Refrigeration sytem shut off at ~ 12:30 today. No apparent reason. Only 
light on was a cold box fault. 
Restarted in parallel cold return mode.