  195   Wed May 2 16:28:16 2007 Doug PreddyNormal RunningEnergizing solenoid to 500 ampsPower supply initially would not ramp up.
I exercised the rate control 
selector switch and found that the power
  
  203   Sat Jun 16 15:05:03 2007 Doug PreddyNormal RunningSolenoid power lead temp problemPower lead temps rippling and increasing.
I asked an operator to cycle 
HIC142. This seems to have fixed the problem
  
  205   Sun Jul 1 16:09:37 2007 Doug PreddyNormal RunningM9B:DP2 tripped off Diffusion pump tripped off and vacuum (and
power lead temps) going up. I 
had an experimentor cycle HIC 142 at 4:15
  
  207   Thu Jul 5 03:04:50 2007 Doug PreddyNormal RunningPower lead problemsThe power leads temps are starting to cycle
again. Earlier today M9 
experimentor cycled HIC142 to stablize the
  
  212   Tue Jul 31 07:53:57 2007 Kevin TrithardtNormal Runningcycled power leadsgot a page for the power lead temp
came down and cycled the power leads.. did
not seem to make a difference..
  
  215   Tue Aug 14 12:55:12 2007 Doug PreddyNormal RunningStrip tool savesThere are two strip tools saved:
coils
powerlead
  
  224   Tue Oct 2 13:02:37 2007 Doug PreddyNormal RunningPLC problemsWhile downloading new code for 2A PLC the
M9 and M15 vacuum systems were 
shut off. This is due to the two systems
  
  237   Fri Nov 23 08:35:37 2007 Doug PreddyNormal Runningpower lead problemsAbout 10 hours ago the power lead temperatures
started to fluctuate and 
climb.
  
  238   Fri Nov 23 08:41:45 2007 Doug PreddyNormal Runningscreen grab of powerlead temps   Capture.jpg 
  239   Mon Nov 26 09:45:43 2007 Doug PreddyNormal Runningpower lead problemsPower lead temperatures were rippling yesterday
afternoon. I asked one of 
the operators to cycle CV142.
  
  240   Tue Nov 27 21:02:08 2007 Doug PreddyNormal Runningpower lead ripplespower leads were oscillating tonight. John
K. came down and cycled CV142. 
(Thanks John!) Temps settling out.
  
  244   Wed Apr 16 15:12:01 2008 Doug PreddyNormal Runninggraphs to loadThere are three strip tools saved:
coils
powerlead
startup
  
  248   Mon Apr 28 09:03:22 2008 Doug PreddyNormal Runningpower leads warmed during weekendThe power lead temperatures suddenly rose
on Sunday morning. No rippling occured before
the woarm up. 
I shut flow off this morning
  
  250   Tue Jul 15 08:47:13 2008 Doug PreddyNormal RunningScreen grab of normal runningSolenoid was recovered on Sunday July 13.
The power leads started to ripple slightly
this morning, so I cycled HIC142. No real
 july_15_08_0841.jpgjuly_15_08_0846.jpg 
  257   Thu Sep 4 10:02:55 2008 Doug PreddyNormal Runningramping down solenoidSolenoid power supply will be turned off for
Fall shutdown.
  
  262   Sun Oct 5 11:12:48 2008 Doug PreddyNormal RunningM9B:V1 interlocks and a IOC crashM9A:V1 was removed this shutdown. It's "in"
limit is required to allow M9B:V1 to be opened.
I have bypassed the interlocks on M9B:V1
  
  264   Wed Nov 5 16:33:52 2008 Doug PreddyNormal Runningsbplc light outOn main menu the sbplc light was black. All
vacuum systems looked good, but there was
no control of any device. Jane reset the
  
  273   Mon Oct 5 11:54:58 2009 Doug PreddyNormal RunningSwitched TIC121 into auto mode    
  286   Fri Nov 12 16:54:50 2010 Doug PreddyNormal RunningSolenoid ramped up    
  2   Fri Dec 19 13:07:25 2003 Willy AnderssonMaintenanceTo-Do list for M9SOLI had distributed this list by email earlier
this month. I have added
a few items at the bottom. I am posting it
 M9Blist3.txt 