  195   Wed May 2 16:28:16 2007 Doug PreddyNormal RunningEnergizing solenoid to 500 amps
Power supply initially would not ramp up. I exercised the rate control 
selector switch and found that the power supply would ramp up at only the 
30 minute setting. It is ramping up at a rate of about 60 minutes.
  203   Sat Jun 16 15:05:03 2007 Doug PreddyNormal RunningSolenoid power lead temp problem
Power lead temps rippling and increasing. I asked an operator to cycle 
HIC142. This seems to have fixed the problem (for now).
  205   Sun Jul 1 16:09:37 2007 Doug PreddyNormal RunningM9B:DP2 tripped off
Diffusion pump tripped off and vacuum (and power lead temps) going up. I 
had an experimentor cycle HIC 142 at 4:15 this morning. When I got in 
today I restarted the pump and it is back to 6.0 x 10-7. Power lead temps 
also are going down.
  207   Thu Jul 5 03:04:50 2007 Doug PreddyNormal RunningPower lead problems
The power leads temps are starting to cycle again. Earlier today M9 
experimentor cycled HIC142 to stablize the oscillations. They started 
again early this morning, so cycled HIC142 again. Oscillations died back, 
but are still present. Will try and warm the power leads later today when 
the experiment's sample is changed.
  212   Tue Jul 31 07:53:57 2007 Kevin TrithardtNormal Runningcycled power leads
got a page for the power lead temp
came down and cycled the power leads.. did not seem to make a difference..

Kevin
  215   Tue Aug 14 12:55:12 2007 Doug PreddyNormal RunningStrip tool saves
There are two strip tools saved:
coils
powerlead
  224   Tue Oct 2 13:02:37 2007 Doug PreddyNormal RunningPLC problems
While downloading new code for 2A PLC the M9 and M15 vacuum systems were 
shut off. This is due to the two systems piggybacking onto the 2A PLC.
When M9 Epics came back up there was no controls. Eventually I reset the 
local/remote switch (thumbwheel #100) to button #1 being on. Mike Leross 
added a text and light on the epics vacuum page that says "EPICS works 
only when green". If this light is not green, dial thumbwheel #100 and 
push button #1. Make sure the light comes on and you should have EPICS 
control back.

This caused a glitch in the refrigerator system. It did not trip it off, 
but it would have if the solenoid was energised. The panel showed 
compressor fault and the temps for TI121, and the powerleads all jumped.
This may be a cause for some of our unknown problems.
  237   Fri Nov 23 08:35:37 2007 Doug PreddyNormal Runningpower lead problems
About 10 hours ago the power lead temperatures started to fluctuate and 
climb.
I cycled CV142 and the Temps have dropped and stablized.
  238   Fri Nov 23 08:41:45 2007 Doug PreddyNormal Runningscreen grab of powerlead temps
Attachment 1: Capture.jpg
Capture.jpg
  239   Mon Nov 26 09:45:43 2007 Doug PreddyNormal Runningpower lead problems
Power lead temperatures were rippling yesterday afternoon. I asked one of 
the operators to cycle CV142.
The temperatures were rippling again this morning, so I cycled CV142.
  240   Tue Nov 27 21:02:08 2007 Doug PreddyNormal Runningpower lead ripples
power leads were oscillating tonight. John K. came down and cycled CV142. 
(Thanks John!) Temps settling out.
  244   Wed Apr 16 15:12:01 2008 Doug PreddyNormal Runninggraphs to load
There are three strip tools saved: coils powerlead startup
  248   Mon Apr 28 09:03:22 2008 Doug PreddyNormal Runningpower leads warmed during weekend
The power lead temperatures suddenly rose on Sunday morning. No rippling occured before the woarm up. I shut flow off this morning for about 10 minutes (until the LHe in went up to 30K) and then open the flow back up. The temperature seem to be recovering.
  250   Tue Jul 15 08:47:13 2008 Doug PreddyNormal RunningScreen grab of normal running
Solenoid was recovered on Sunday July 13. The power leads started to ripple slightly this morning, so I cycled HIC142. No real change.
Attachment 1: july_15_08_0841.jpg
july_15_08_0841.jpg
Attachment 2: july_15_08_0846.jpg
july_15_08_0846.jpg
  257   Thu Sep 4 10:02:55 2008 Doug PreddyNormal Runningramping down solenoid
Solenoid power supply will be turned off for Fall shutdown.
  262   Sun Oct 5 11:12:48 2008 Doug PreddyNormal RunningM9B:V1 interlocks and a IOC crash
M9A:V1 was removed this shutdown. It's "in" limit is required to allow M9B:V1 to be opened. I have bypassed the interlocks on M9B:V1 until the M9A:V1 limits can be jumpered. Don Dale and George Clark have been informed. Also an IOC crashed so the data pages were not updating. Evgeny rebooted the IOC. All is now fixed.
  264   Wed Nov 5 16:33:52 2008 Doug PreddyNormal Runningsbplc light out
On main menu the sbplc light was black. All vacuum systems looked good, but there was no control of any device. Jane reset the IOC. It is hosted by sundance.
  273   Mon Oct 5 11:54:58 2009 Doug PreddyNormal RunningSwitched TIC121 into auto mode
  286   Fri Nov 12 16:54:50 2010 Doug PreddyNormal RunningSolenoid ramped up
  2   Fri Dec 19 13:07:25 2003 Willy AnderssonMaintenanceTo-Do list for M9SOL
I had distributed this list by email earlier this month. I have added
a few items at the bottom. I am posting it on the M9SOL Elog under
Maintenance. Some of the items may not be achievable or practical but
I thought it would be a useful first attempt at a To-Do list.
Attachment 1: M9Blist3.txt
To-do and To-consider items for M9B superconducting 
solenoid/refrigeration system.

- New pressure guages for the Mycom compressor panel. The 
present guages are damaged from vibration and do not read 
properly. The new guages should be isolated somehow from 
vibration. 

- Investigate designing and building a compressor oil 
heater/conditioner. The helium compressor should be topped up 
with "conditioned" oil. 

- Have contractor check allignment of compressor motor to 
compressor and check flex coupling condition. MYCOM to 
recommend contractor. Check condition of and re-grease 
compressor motor bearings. 

- Replace missing and unreadable identification tags on 
valves, piping, and instrumentation throughout the system. 

- Identify, catalog and label stored spare parts and equipment 
and provide proper storage. 

- Provide "Lamp Check" button for main compressor panel. 

- Investigate LED type replacement bulbs ( Base Style 24XX ) 
for Sulzer control panel. 

- Update and improve operation manual and maintenance instructions. 

- Provide computer control for solenoid power supply to 
simplify operation and make it less prone to operator 
error. 

- Re-arrange locations of vacuum computer and X displays so 
that the opportunity of accidently bumping into buttons on Sulzer 
panel is reduced. 

- Re-write solenoid power supply logic to require that both powerlead 
temperatures must be stable and below XX? Kelvin for 60 minutes before 
enabling arming the solenoid power supply. 

- Increase computer security. Restrict physical access ? 
Virus scanner ? 

- Look into using Ultra-VNC with encryption for security. Stop 
Commute modem access but route Commute access through hard wired 
serial connection to PC running Ultra-VNC. Or keep modem access 
but use call back method. 

- Set up procedure and pipe in convenient sample points for 
dewpoint, N2/O2, oil content readings. Sample readings should be 
documented prior to starting turbine cooling. 

- Upgrade LN2 fill equipment for Purifiers. Can both puifiers 
be operated in parallel during a cool down ? Auto-isolation of 
purifiers' from helium system when LN2 runs out or fails or 
power failure. 

- Provide dedicated LN2 line to M9B compressor building ? Guy Stanford 
has info on relatively inexpensive efficient foam covering for LN2 
lines instead of vacuum jacketed piping. 

- Can anything be done about the epoxy fumes from the buffer tank ? 
A charcoal/molecular seive filter in the buffer tank line 
check-valved for free flow to buffer but filtered flow from buffer ? 

- Fix back-up air compressor system. 

- Remove any unauthorized taps off of the M9B compressed air line to 
other non M9B systems. 

- Clean-up of compressor building and clean-up around Sulzer panel. 

- Route turbine defrost circuits to outside of shielding blocks. 

- Clean-up area behind solenoid power lead flowmeters and pressure 
gauge panel. Remove all unused tubing and cables. 

- Harden Sulzer control panel against water damage from water leaks 
overhead. 

- pipe in precision flow control valve and pressure guages on powerlead 
flow to main compressor suction line. 

- pipe in manual bypass circuit around main coldbox HE in and out 
valves. 

- New vacuum controller for Sulzer panel. Repair old one for a spare. 

- Add in some smart logic to prevent system trip on solenoid vacuum 
during a quench recovery cooldown. When solenoid power supply is 
not armed solenoid vacuum should be allowed to degrade slightly 
( within limits ) from contamination defrosting into solenoid vacuum. 
As soon as solenoid power supply is armed then solenoid vacuum trip 
set to high vacuum again. Solenoid vacuum trip logic should be re-worked. 

- provide vacuum gauge between solenoid vacuum diffpump and BV2. 

- provide computer readable indication for: 

        - CV204 position 
        - LHe heater reading 
        - turbine 1 entrance temp. 
        - Buffer tank line pressure 
        - air pressure 
        - position signal to CV211 and CV212 
        - position of CV151 
        - position of CV141 
        - 80K shield heater setting 
        - purifier LN2 status 
        - backup air compressor OK 
        - solenoid vacuum 
        - solenoid current 
        - solenoid power supply armed ? 
        - others ????? 


- check oil levels, drive belts etc for system mechanical, diff, and 
cryo pumps. 

- check calibration of system pressure and temperature sensors. 

- repairs and upgrades to Sulzer Control panel instrumentation and 
relays 

- re-charge TI148 and TI149 

- follow-up on improvement requests for X displays for vacuum and solenoid 
data. 

- compressor water package maintenance and repairs. 

- repair compressor building roof leak. 

- inspect and clean system air filters and coalesers and water filters. 

- buffer tank clean-up and re-paint. 

- train more system operators for M9B and ISAC II helium refrigeration 
systems ? 

- Vacuum gauges on cold box transfer lines ? Or build small portable LN2 
trapped vacuum pump station ( probably very usefull for many other 
areas at TRIUMF including purifier regeneration in compressor building ) 

- Should we buy Don Dales' first trip logger ? It is a PLC that is networkable 
and may be used for other functions ? Is it obsolete or outdated ? 

- Develope a system using a residual gas analyzer for helium gas purity 
measurements ? 

_____________________________________________________________________________ 

Items added Dec 19,2003 :

- Sniffer Leak check of piping, especially powerlead insulators.

- Top up gas to system. The lowest helium relief valve setting is
SV45 set at 5 kg/cm^2 Gauge  (71.12 psig) so it would be reasonable
to fill the system to 60 psig.

- re-work purifier plumbing, add purge ports at flowmeter. Make
purifiers portable ?

- Make small portable circulation helium compressor + ORS skid ?

- Schedule quarterly steady state vibration measurments for MYCOM 
compressor. (Tom Ries has vibration measurement equipment)

_______________________________________________________End of list for now !