> The solenoid was pumped out Monday and yesterday after the quads just > downstream of the solenoid were put back in place. The quad just > downstream of the solenoid was remove to replace two coils on it. > The cold box vacuum had tripped off some time in the last little while. > Started it pumping on Monday also. The compressor was started Tuesday > afternoon and flow was started to the solenoid. The purifier was > regenerated and put on line in it's total buffer tank flow mode. The cold > box was pressurized and the turbines were briefly spun up to check the > operation of the new turbine speed indicator. It seems to be working > properly. > Flow to the turbines was started this morning and all went well. The speed > indicator works properly. > M9BIG1 started ot 6.6 x 10-6 before flow was started. One hour later it > reads 4.8 x 10-6