M9sol Logbooks
Solenoid
Daily log
Solenoid logbook
Fields marked with
*
are required
Entry time:
Thu Jan 1 12:44:17 2026
Author
*
:
- please select -
Doug Preddy
Curtis Ballard
Kevin Trithardt
David Kishi
Experimentor
Other
Operational Mode:
- please select -
Normal Running
Quench Recovery
Start Up
Shut Down
Maintenance
Other
Subject
*
:
> When the compressor was restarted on Monday, the remote load button would > not respond. The compressor was shut off. After two days of searching the > wiring etc. a bad connection was found on DR1 relay (upstairs in the > compressor control panel). The wire was the "compressor on" sensor. > Connection was cleaned and retightened. > The compressor was started this morning and is working. > I pressurized the cold box and started flow to the solenoid and through the > power leads. I started a continuous flow throughthe LN2 adsorber. This will > be run over the weekend. Cooling to start Monday morning.
Encoding
:
HTML
ELCode
plain
Suppress Email notification
Attachment 1:
ELOG V2.9.2-2455