Tuda logbooks
General
E1104
ISACII
E1195
E1103
E1147
S1287
S1203
S1233
S1284
S1447 23Na(a,p)
S1540
S1381
S1847 Catania
S1287
Fields marked with
*
are required
Entry time:
Wed Apr 13 03:43:42 2011
Author
*
:
Type:
- please select -
Routine
Other
Category:
- please select -
General
Other
Subject:
<p>2um x 8 mm Ni windows leaked tested on TUDA gas cell. With window placed on the outside of the cell, cell was evacuated and pressure monitored with time, i.e. 1atm differential air pressure. Comparison to leak rate with blank flange also do.</p> <p>Tests were performed in order: Ni, 30 minuets pumping, Ni again, blank, Ni third time.</p> <p>Plots are the same data, different scales.</p>
Encoding
:
HTML
ELCode
plain
Suppress Email notification
Resubmit as new entry
Attachment 1:
Screenshot.png
Original size: 918x470
Attachment 2:
Screenshot-1.png
Original size: 907x460
Attachment 3:
ELOG V2.9.2-2455