Entry time:
Thu Nov 14 20:45:48 2024
Author
*
:
Type:
- please select -
Routine
Other
Category:
- please select -
General
Other
Subject:
tuda2 (by TUDA chamber, SEBT1) was powered off on arrival - this may have been due to a previous power outage between March 18-April 4. Rebooted OK. MIDAS DAQ operational MIDAS DAQ reads out CAEN V560 Scaler #1 channels #0-7 (see file VMEDataSources below) on a per event basis. Data directory tuda2:/data2/data/S1287 S1287 requires 64+64+32+16=176 channels of ADCs/TDCs i.e. 6x Silena 9418/6V ADCs and 2x CAEN V1190A TDCs. Currently configured for 11x ADCs, 3x TDCs and 2x Scalers. Note - VME crate #2 (top) displays a yellow 'overheat' warning LED. This is probably bogus - the air and PSU temperatures reported by the front panel look OK. MIDAS DAQ works for mode 'MIDAS Data Acquisition' and 'TUDA'. For the latter, all scalers and the EPICS variables (defined by tuda:/MIDAS/TUDA/tcl/EpicsDefn.tcl - see below) are readout every 20s.