> > Nominal detector configuration for S1287 is as follows: > > > Detector Tgt Ladder #2 > -Detector Nominal LAB Solid > Distance (cm) Angles (deg) Angle (sr) > > S2-1 7.0 9.5-26.4 0.430 > S2-2 28.0 2.4-7.1 0.032 > > W >35.0 0.0-4.1 ~0.020 > > S2-1 MSL type S2(DS)-500 > S2-2 MSL type S2(DS)-500 > W MSL type W(DS)-1000 > > Hardware installed in TUDA chamber is as follows (listing from > upstream to downstream): > > 1 Upstream support collar > > 2 PDs (to monitor Ni window) > PD preamplifier assembly > > 3 4mm dia collimator > CCTV camera? > > Target Ladder - Position #1 - 83cm from inner surface of the downstream flange > 5mm dia anti-scatter collimator > PDs (to monitor 197Au RBS) > > Target Ladder - Position #2 - 75cm from inner surface of the downstream flange > 10mm & 3mm dia tuning apertures, ZnS, PDs, (CH2)n targets > > 4 S2-1 DSSSD > S2 preamplifier assembly > > 5 S2-2 DSSSD > S2 preamplifier > > 6 W DSSSD > W preamplifier assembly (to be shipped to TRIUMF) > > 7 Faraday Cup > > 8 Downstream 4-vane monitor (not used) > > Detector mounts will be within +/-5mm of their nominal positions.