Tuda logbooks
General
E1104
ISACII
E1195
E1103
E1147
S1287
S1203
S1233
S1284
S1447 23Na(a,p)
S1540
S1381
S1847 Catania
S1287
Fields marked with
*
are required
Entry time:
Wed May 11 17:59:12 2011
Author
*
:
Type:
- please select -
Routine
Other
Category:
- please select -
General
Other
Subject:
<p>Alignments checks revealed that downstream end of TUDA was ~1mm off (can't remember which way).</p> <p>Re-entrant flange (window end) found to be ~5mm too low and ~2mm to the left. Checked upstream end of chamber and was ok.</p> <p>Removed bellows etc. and re-entrant flange, replaced with re-entrant flange bolts only figure tight. Tighten bolts from inside chamber whilst checking alignment, adjusting as appropriate.</p> <p>Managed to get to ~0.5mm to the right and ~0.25mm too low.</p> <p>This is acceptable so closed chamber and checked vacuum down to ~150mTorr.</p>
Encoding
:
HTML
ELCode
plain
Suppress Email notification
Resubmit as new entry
Attachment 1:
ELOG V2.9.2-2455