Subject:
10.02 See attachment 1 for overnight EPICS log of TUDA2.CG5 Downstream flange secured by four bolts Current pressure 1.07Torr - rate of increase ~0.2 Torr/5h 11.30 TUDA chamber pumped down to ~800mbar Downstream flange bolts removed - no change in pressure observed N2 bottle connected to TUDA vent valve - to vent and (hopefully) exceed atmospheric pressure forcing downstream flange to move open Pressure measured using MKS Baratron 1000Torr gauge Result - pressure increased from 800 to ~1000mbar in ~45s TUDA chamber pressure did not noticably exceed atmospheric pressure and there was no obvious movement of downstream flange. Gas could be felt escaping from sides of downstream flange. Conclude - contact with downstream flange O-ring failed at, or near, atmospheric pressure - this prevented buildup in excess of atmospheric pressure 11.50 Installed: preamp services (+/-15V preamp power, +/- preamp test inputs) - 10-way IDC ribbon cables detector HT - SMC/BNC cabling preamp signals - 34-way IDC twist-n-flat ribbon cables preamp thermocouple attached to an S2-1 preamplifier 15.00 Time to 250mTorr ~14m Time from 250mTorr to 4.75E-5Torr ~45m See attachment 2 16.04 FTS RS44 set point +5.5 deg C 16.21 FTS RS44 temperature +5.6 deg C 17.12 TUDA2.PNG5 8.2E-06Torr FTS RS44 temperature +5.8 deg C Preamp thermocouple +8 deg C 17.13 +/-15V preamp power ON 17.18 Preamp thermocouple +14 deg C TUDA2.PNG5 8.0E-06Torr 17.23 Preamp thermocouple +14 deg C TUDA2.PNG5 7.9E-06Torr 17.28 Preamp thermocouple +15 deg C TUDA2.PNG5 7.7E-06Torr 17.43 Preamp thermocouple +15 deg C TUDA2.PNG5 7.0E-06Torr CAEN SY403 HV mainframe Channel HT Detector Bias I_L (V) (uA) 1 1 S2-1 -130 -0.03 2 2 S2-2 -130 -0.06 3 3 W -250 -0.02 4 4 PD -30 -0.03 Low leakage currents as expected - no evidence of high resistance shorts All other channels set to 0V +/-15V PSUs #1 +15V/0A -15V/0A (MSL type W preamp not installed) #2 +15V/1.65A -15V/0.65A (2x MSL type S2 + 1x 16ch PD preamp units) 17.58 Preamp thermocouple +13 deg C TUDA2.PNG5 6.3E-06Torr 18.13 Preamp thermocouple +12 deg C TUDA2.PNG5 5.8-06Torr 18.29 Preamp thermocouple +12 deg C TUDA2.PNG5 5.3-06Torr 18.32 +/-15V preamp power OFF FTS RS44 set point +21 deg C 18.39 Cryo gate valve closed Turbo off and isolated 4x bolts securing downstream flange removed Repeat yesterday's leak-in test (bolts removed)
Encoding
:
HTML
ELCode
plain
Suppress Email notification
Resubmit as new entry
Attachment 1:
1.png
Original size: 812x634
Attachment 2:
5.png
Original size: 812x634
Attachment 3:
ELOG V2.9.2-2455