Wednesday, May 16, 2012, 16:01, Anders Mjos, , , , , , , Problems/Solutions, Loose chip of insulator material detected
|
Thursday, May 17, 2012, 12:19, Anders Mjos, SiC#27, HP-SIS, ITE, TM4, , , Problems/Solutions, Loose chip of insulator material detected
|
|
Message ID: 97
Entry time: Thursday, May 17, 2012, 12:19
In reply to: 93
|
Author: |
Anders Mjos |
Target/No.#: |
SiC#27 |
Source: |
HP-SIS |
Station: |
ITE |
Module: |
TM4 |
Target Oven W.O#: |
|
Heat Shield W.O#: |
|
Status: |
Problems/Solutions |
Subject: |
Loose chip of insulator material detected |
|
|
Anders Mjos wrote: |
A chip of insulator material was detected below the lower target insulator stand-off (attachment - left picture). The chip may come from the tube heater insulator above (attachment - right picture). The chip will be further investigated when the target is removed.
|