Logbooks Lab Maintenance Evaporator_1 Evaporator_2 Laser cutter Target Production Test-Stand RH-ISAC RH-Cyclotron RH-Meson Hall RH-Beamlines RH-ARIEL
  Test-Stand  Not logged in ELOG logo
Message ID: 844     Entry time: Thursday, February 04, 2021, 18:48
Author: Fernando Maldonado 
Target/No.#:  
Source: LP-SIS 
Station:  
Module:  
Target Oven W.O#: 44139-10 
Heat Shield W.O#: 44378-2  
Status: Problems/Solutions 
Subject: Energy spread calibration with SIS 

The system was vented to  make clearance on the waterlines as a very small continuous discharge was observed.

The inspection revealed some marks on the HS water line (sideview photo). From the the bottom and from real close (zoom and backview photo) the marks are quite noticeable with shinny copper in the middle and dark circles around.

The GND line is routed in such a way that sits on top of the ion gauge chamber (gnd-ig1) this could explain why the vacuum had small oscillation during the current limited events.

Moreover, the GND line has the steerer cables tied to it, this could explain why one of the steerers got affected after the sparks.

Also, the GND line is in contact with a dark grime that goes all the way into the first skimmer (gnd-quad). I think the grime observed inside the test stand might have become conductive, or if this is trace from a previous flashover, this  is good path to flash again.

 

The EE and the plasma electrode were removed and they show signs of buildup. Cleaned and reinstalled

Attachment 1: sideview.png  776 kB  Uploaded Friday, February 05, 2021, 08:27  | Show | Hide all
Attachment 2: zoom.png  304 kB  Uploaded Friday, February 05, 2021, 08:27  | Show | Hide all
Attachment 3: bottom_view.png  283 kB  Uploaded Friday, February 05, 2021, 08:27  | Show | Hide all
Attachment 4: gnd-ig1.png  390 kB  Uploaded Friday, February 05, 2021, 08:27  | Hide | Hide all
gnd-ig1.png
Attachment 5: gnd-steerers.png  219 kB  Uploaded Friday, February 05, 2021, 08:28  | Show | Hide all
Attachment 6: gnd-quad.png  478 kB  Uploaded Friday, February 05, 2021, 08:28  | Show | Hide all
ELOG V2.9.2-2455