Logbooks Lab Maintenance Evaporator_1 Evaporator_2 Laser cutter Target Production Test-Stand RH-ISAC RH-Cyclotron RH-Meson Hall RH-Beamlines RH-ARIEL
  Test-Stand  Not logged in ELOG logo
Message ID: 77     Entry time: Friday, April 20, 2012, 08:56
Author: Anders Mjos 
Target/No.#: Nb#6 
Source: LP-SIS 
Station: ITW 
Module: TM1 
Target Oven W.O#:  
Heat Shield W.O#:  
Status: Problems/Solutions 
Subject: Insulator stand-off failure 

 When the target was removed from the test stand it was discovered that the custom designed insulator stand-off (ITD0400 made from Mycroy 1100) had swollen and become discoloured in the area exposed to "heat shine" from the target oven. See attached pdf for photos of the insulators.

The heat shield lid was opened up and the target temporarily removed to replace the two insulators that had failed. These were replaced with the commercially available glazed steatite stand-offs. The target had some marks from the insulators which was cleaned with acetone and methanol.

After replacing the insulators, the target assembly was assembled, leak checked and a new electrical check was performed.

 

Additional photos are available on DocuShare

Attachment 1: ITW-TM1-Nb#6-LP-SIS_-_TestStand.pdf  209 kB  | Hide | Hide all
ITW-TM1-Nb#6-LP-SIS_-_TestStand.pdf
ELOG V2.9.2-2455