Conditioning Data Sheet,Data Entry,notes,Notes for operator ,,, Operator,Dave Neilson,, Elog Number,1048,, Target #,-,, Target Oven WO#,,, Heat Shield WO#,45235-5,, ,,, Conditioning current,,, TGHT (default 580),580,, TBHT (default 230),230,, ,,, Conditioning voltages,,, HV BIAS (max),41.5,, Einzel Lens (BIAS - 17kV),33,, Time at max,75,, Final Spark Period,25,,"On average, time between sparks at HV MAX" ,,, Data Output (30kV tune),,, FC0 output,2.12E-08,, Mass Scan filename,2025-04-23 C#5 conditioning mass scan,, RPM0A filename,2025-04-23 C#5 RPM0A_1nA,,"right click plot, 'dump to file', enter file name ""YYYY-MM-DD_hh-mm RPMXX.txt""" RPM0B filename,2025-04-23 C#5 RPM0B_1nA,, RPM6A filename,2025-04-23 C#5 RPM6A_33nA,40, RPM6B filename,2025-04-23 C#5 RPM6B_33nA,40, ,,, Peak,Max,, 7,1.66E-10,, 23,1.66E-10,, 27,5.86E-10,, 39,4.20E-11,, 40,3.06E-09,, 48,1.02E-11,,