Logbooks Lab Maintenance Evaporator_1 Evaporator_2 Laser cutter Target Production Test-Stand RH-ISAC RH-Cyclotron RH-Meson Hall RH-Beamlines RH-ARIEL
  Target Production  Not logged in ELOG logo
Message ID: 92     Entry time: Tuesday, September 17, 2019, 08:47
Author: Aaron Schmidt 
Target/No.#: Ta#59 
Source: LP-SIS 
Station:  
Module: TM2 
Target Oven W.O#: 44062-5 
Heat Shield W.O#:  
Status: In progress 
Subject: Ta#59 Target description 

Tuesday, September 17, 2019, 08:44: 

Ta#59 LP-SIS target description:

Total Ta foils = 470 [6x20 packs + 350 single discs]

Foil Thickness = 0.025mm

Target density =  13.74 g/cm3

Target length = 3.4 cm

Total Mass =  46.7314 g [Incl foils + Ta wire on 6 packs]

Total mass w/ Target oven=  436 g (440 g w/ end caps)

Discs in target are arranged as follows: 1pack / 75singles / 1pack / 100singles / 2packs / 100singles / 1pack / 75singles / 1pack

End caps installed (not yet expanded). No Ta heat shield added.

Attachment 1: Ta#59_Loading_Data.pdf  105 kB  Uploaded Tuesday, September 17, 2019, 09:53  | Hide | Hide all
Ta#59_Loading_Data.pdf
ELOG V2.9.2-2455