Logbooks Lab Maintenance Evaporator_1 Evaporator_2 Laser cutter Target Production Test-Stand RH-ISAC RH-Cyclotron RH-Meson Hall RH-Beamlines RH-ARIEL
  Target Production  Not logged in ELOG logo
Message ID: 89     Entry time: Friday, May 31, 2019, 16:11
Author: Aaron Schmidt 
Target/No.#: Ta#58 
Source: LP-SIS 
Station: ITE 
Module: TM2 
Target Oven W.O#: 43044-4 
Heat Shield W.O#: 42972-7 
Status: Ready 
Subject: Ta#58 Target desription 

 Ta#58 LP-SIS target description:

Total Ta foils = 470 [6x20 packs + 350 single discs]

Foil Thickness = 0.025mm

Target density =  14.16 g/cm3

Target length = 3.4 cm

Total Mass =  48.138 g [Incl foils + Ta wire on 6 packs]

Total mass w/ Target oven=  464 g

Discs in target are arranged as follows: 1pack / 75singles / 1pack / 100singles / 2packs / 100singles / 1pack / 75singles / 1pack

End caps installed (not yet expanded). No Ta heat shield added.

Attachment 1: Ta#58_Loading_data.pdf  129 kB  Uploaded Wednesday, December 04, 2019, 10:36  | Show | Show all
ELOG V2.9.2-2455