Logbooks Lab Maintenance Evaporator_1 Evaporator_2 Laser cutter Target Production Test-Stand RH-ISAC RH-Cyclotron RH-Meson Hall RH-Beamlines RH-ARIEL
  Target Production  Not logged in ELOG logo
Message ID: 85     Entry time: Monday, September 17, 2018, 11:39
Author: John Wong 
Target/No.#: np-SiC#1 
Source: LP-SIS 
Station:  
Module:  
Target Oven W.O#: 43044-1 
Heat Shield W.O#:  
Status: Ready 
Subject: nano-SiC#1 Target description 

Monday, September 17, 2018, 11:32

See attachment for the target description.

Some notes about the target conditioning in Evap#2 (see elog ID#414):

TGHT at 500A, 8.4V, temp at 1600 C (4.2 kW)

TGHT at 475/7.84V, temp at 1550 C (3.72 kW - Max operating target heating power)

TGHT at 450/7.31V, temp at 1500 C (3.28 kW)


 

Attachment 1: target_description.JPG  36 kB  | Show | Show all
ELOG V2.9.2-2455