Logbooks Lab Maintenance Evaporator_1 Evaporator_2 Laser cutter Target Production Test-Stand RH-ISAC RH-Cyclotron RH-Meson Hall RH-Beamlines RH-ARIEL
  Target Production  Not logged in ELOG logo
Message ID: 82     Entry time: Thursday, June 21, 2018, 11:34
Author: Aaron Schmidt 
Target/No.#: Ta#56 
Source: HP-SIS 
Station:  
Module:  
Target Oven W.O#: 42218-9 
Heat Shield W.O#:  
Status: Ready 
Subject: Ta#56 target description 

 Thursday, June 21, 2018, 11:33:

Ta#56 HP-SIS target description:

Total Ta foils = 470 [6x20 packs + 350 single discs]

Foil Thickness = 0.025mm

Target density = 14.01 g/cm3

Target length = 3.4 cm

Total Mass = 47.374 g [Incl foils + Ta wire on 6 packs]

Total mass w/ Target oven= 1469 g

No endcaps inserted, no Rh foil inserted.


Tuesday, July 03, 2018, 08:30: Endcaps inserted & expanded. Rh foil inserted.

Attachment 1: Ta#56_Loading_Data.pdf  50 kB  Uploaded Monday, June 25, 2018, 15:17  | Hide | Hide all
Ta#56_Loading_Data.pdf
ELOG V2.9.2-2455