Logbooks Lab Maintenance Evaporator_1 Evaporator_2 Laser cutter Target Production Test-Stand RH-ISAC RH-Cyclotron RH-Meson Hall RH-Beamlines RH-ARIEL
  Target Production  Not logged in ELOG logo
Message ID: 22     Entry time: Friday, June 01, 2012, 11:43
Author: John Wong 
Target/No.#: Ta#38 
Source: LP-SIS 
Station: ITW 
Module: TM1 
Target Oven W.O#: 39165-2 
Heat Shield W.O#: 38633-2 
Status: Spent 
Subject: Ta#38 target description 

Ta#38 LP-SIS target description:

Total Ta foils = 400

Foil thickness = 0.025mm

Target density = 16.69 g/cm3

Target area = 2.12cm2

Target length = 4.3cm

Total Mass (400 foils + Ta wire) = 42.8013g

See the link for more details: http://documents.triumf.ca/docushare/dsweb/View/Collection-8541


Friday, June 01, 2012, 11:36

The target is now in the test-stand, and by next week Tuesday, it should go in the Hotcell.

 


 Monday, June 04, 2012, 16:56

The target was tested in the Test-stand.  The EE was inspected and a small amount of deposit was discovered after the test (the same stuff was found on Ta#36),  see attachment #1.  The samples were collected and will be analyzed through SEM/EDX/XRD.

The EE and the common plate were cleaned with methanol and were assembled back.

The target is ready to go in the Hotcell tomorrow, June 05.


 Monday, November 05, 2012, 16:42

The deposits on the EE and CC were analyzed using XRD

On the EE, it was mainly copper hydroxide nitrate, Cu2(OH)3(NO3). (see attachment #2)

On the CE, it was mainly tantalum, Ta. (see attachment #3)


 

Attachment 1: Ta_38_EE_deposit.JPG  124 kB  Uploaded Monday, June 04, 2012, 17:59  | Hide | Hide all
Ta_38_EE_deposit.JPG
Attachment 2: Ta#38_EE.PNG  42 kB  Uploaded Monday, November 05, 2012, 16:47  | Show | Hide all
Attachment 3: Ta#38_CE.PNG  39 kB  Uploaded Monday, November 05, 2012, 16:48  | Show | Hide all
ELOG V2.9.2-2455