Logbooks Lab Maintenance Evaporator_1 Evaporator_2 Laser cutter Target Production Test-Stand RH-ISAC RH-Cyclotron RH-Meson Hall RH-Beamlines RH-ARIEL
  Target Production  Not logged in ELOG logo
Message ID: 147     Entry time: Monday, October 07, 2024, 13:16
Author: Aaron Schmidt 
Target/No.#: Ta#68 
Source: HP-SIS 
Station: ITE 
Module: TM2 
Target Oven W.O#: 45447-26 
Heat Shield W.O#: 45235-16 
Status: Ready 
Subject: Ta#68 Target Description 

 Ta#68 HP-SIS target description: 

Total Ta foils = 470 [6x20 packs + 350 single discs]

Foil Thickness = 0.0254mm (0.0010") avg Measured. 

Target material batch: PO# TR-2023-06149

Target density = 14.204 g/cm3

Target length = 3.50 cm

Total Mass = 49.7146 g [Incl foils + Ta wire on 6 packs]

Total mass w/ Target oven =  1483g (w/ end caps)

Discs in target are arranged as follows: 1pack / 75 singles / 1pack / 100 singles / 2packs / 100 singles / 1pack / 75 singles / 1pack

Dimpling direction on foils/ Packs.                                                               --> Center <--

End caps installed (Expanded). No Ta foil heat shield added

Attachment 1: ITE-TM2-Ta#68-HP-SIS_Target_Loading_Data.pdf  61 kB  | Hide | Hide all
ITE-TM2-Ta#68-HP-SIS_Target_Loading_Data.pdf
ELOG V2.9.2-2455