Logbooks Lab Maintenance Evaporator_1 Evaporator_2 Laser cutter Target Production Test-Stand RH-ISAC RH-Cyclotron RH-Meson Hall RH-Beamlines RH-ARIEL
  Target Production  Not logged in ELOG logo
Message ID: 135     Entry time: Thursday, August 24, 2023, 14:16
Author: Aaron Schmidt 
Target/No.#: Nb#11 
Source: LP-IG-LIS 
Station: ITW 
Module: TM2 
Target Oven W.O#: 45447-9 
Heat Shield W.O#:  
Status: In progress 
Subject: Nb#11 Target description 

Nb#11 LP-IG-LIS target description:

Total Ta foils = 470 [6x20 packs + 350 single discs]

Foil Thickness = 0.025mm (0.001")

Target density =  7.13 g/cm3

Target length = 3.53 cm

Total Mass = 25.165 g [Incl foils + Ta wire on 6 packs]

Total mass w/ Target oven=  434 g (w/ end caps)

Discs in target are arranged as follows: 1pack / 75 singles / 1pack / 100 singles / 2packs / 100 singles / 1pack / 75 singles / 1pack

Dimpling direction on foils/ Packs.                                                               --> Center <--

End caps installed (Not expanded). No Ta foil heat shield added

Replacement for Nb#10

Attachment 1: Nb#11_Target_Loading_Data.pdf  34 kB  Uploaded Monday, August 28, 2023, 13:56  | Show | Show all
ELOG V2.9.2-2455