Message ID: 288
Entry time: Thursday, April 14, 2022, 14:38
|
Author: |
Adam Newsome |
Category: |
Other |
Type: |
Target 2 |
Specific: |
Diagnostics |
Subject: |
Issue with Protect Monitor SHV Cable |
|
|
Diagnostics group (Shengli Liu) noted a lack of connectivity between control panel and T2 Protect Monitor via the high voltage cable. Upon inspection it was noted:
- The cable was very brittle due to radiation exposure and it was cracking in multiple places
- In the SHV connector, the pins were slightly bent (bending them back into position seemed to rectify the connectivity issue).
- The cable was bent at the strain relief junction
RH Group has advised that Diagnostics replace the entire cable as soon as possible. For now it appears to be working. |
|
|
|
|