Message ID: 896     Entry time: Thursday, April 23, 2015, 09:08
Author: David Wang 
Category: Conditioning Station 
Type: Maintenance 
Module: TM1 
Target/Number: UCx12 
Subject: Huge Leak on TM1 contaiment box window. 

There is a huge leak on TM1 containment box window. I did a 70 psi helium pressure test on all TM1 water circuits this morning. The LD base leak rate was 0.0XE-9 atm.cc/sec. When applying the 70 psi helium to containment box window circuit, the leak rate on LD jumped to 1XE-4 atm.cc/sec in 5 seconds.I released the helium source right away,t but the conditioning station is full of helium  molecules already, and the leak rate on LD stays at 1xE-5 atm.cc /sec.  The leak on this circuit is huge.    Other water lines are good.        

Attachment 1: 006.JPG  2.044 MB  | Show | Show all
Attachment 2: 008.JPG  2.522 MB  | Show | Show all
Attachment 3: 011.JPG  2.275 MB  | Show | Show all
Attachment 4: 009.JPG  3.115 MB  | Show | Show all
Attachment 5: TM1_leak_check_at_CS_2015-04-23.pdf  149 kB  | Show | Show all