Logbooks
Lab Maintenance
Evaporator_1
Evaporator_2
Laser cutter
Target Production
Test-Stand
RH-ISAC
RH-Cyclotron
RH-Meson Hall
RH-Beamlines
RH-ARIEL
|
RH-ISAC |
Not logged in |
 |
|
Wednesday, April 30, 2014, 12:03, Travis Cave, Spent Target Vault, Standard Operation, , 2A3 window, Window now in vault
|
Friday, March 24, 2017, 11:19, Keith C Ng, Spent Target Vault, Standard Operation, , 2A3 window, Window now in vault
|
|
Message ID: 653
Entry time: Wednesday, April 30, 2014, 12:03
Reply to this: 1462
|
Author: |
Travis Cave |
Category: |
Spent Target Vault |
Type: |
Standard Operation |
Module: |
|
Target/Number: |
2A3 window |
Subject: |
Window now in vault |
|
|
The 2A3 window now has a lid, and lift yolk on it and it has been installed in the spent target vault in spot 2A. The lid is a normal unmodified and has no sealant on it. |
|
|