Message ID: 592
Entry time: Tuesday, February 04, 2014, 09:42
|
Author: |
David Wang |
Category: |
South Hot-Cell |
Type: |
Repair |
Module: |
TM2 |
Target/Number: |
|
Subject: |
pressure test on TM2 tube heater +(D) water line. |
|
|
Chad and I did a pressure test on TM2 tube Heater+(D) water line.I pressurized the D line with shop air from quick connectors(both ends) on service cap.chad applied bubble soap onto the D water block in SHC. The test started from 5psi,and increased 5psi each time to 40 psi. From 5 to 35 psi, no bubble has been found on water block. At 40 psi , bubble appeared from blind blank off seal , but not from soldering joints. Since the o-ring seal for the blank off is vacuum seal , but not for pressurizing, It is understandable the seal could not hold 40 psi pressure air. No bubble had been found on the D water block soldering joints .See attachment pictures. |
|
|
|
|
|
|
|
|
|
|
|