Message ID: 476     Entry time: Friday, September 27, 2013, 12:53
Author: Bevan Moss 
Category: Conditioning Station 
Type: Standard Operation 
Module: TM3 
Target/Number: NiO#2 
Subject: HP TGHT and TBHT conditioning 

 Yesterday TM3 had the TGHT current raised to 160 amps and the TBHT raised to 200 amps. At this power the TGHT showed typical results in that vacuum was affected and the increased voltage as the target increased in temperature. The tube heater on the other hand did not change voltage or show a change in vacuum. As a result it is believe there is a short somewhere in the module. I have attached a screen shot of the strip tool and the raw data.

Attachment 1: 26092013_TM3_NiO#2_HP_testing.JPG  113 kB  | Show | Show all
Attachment 2: 26092013_TM3_NiO2_HP_testing.txt  1.747 MB  | Show | Show all