Message ID: 454     Entry time: Friday, September 13, 2013, 08:05
Author: David Wang 
Category: South Hot-Cell 
Type: Repair 
Module: TM4 
Target/Number:  
Subject: TM4 coil 1 leak check in SHC 

Leak checked TM4 coil1 in SHC with Isaac . The leak detector only can pump down to 1.5xE-7 atm.cc/sec. The leak detector got the response once the helium valve is open, not even close to the leak area. The leak detector got a very big response when the helium probe was put close to the coil terminal block on target front side and spray helium for 2 clicks. The leak detector got a small  response when the probe was put close to water block area and spray helium for 2 clicks. The leak is located on the front target side coil line but not from water blocks. The leak is too big to be further pin pointed by this method. See attachment

Attachment 1: TM4_coil_1_leak_check.pdf  201 kB  | Show | Hide all