Logbooks Lab Maintenance Evaporator_1 Evaporator_2 Laser cutter Target Production Test-Stand RH-ISAC RH-Cyclotron RH-Meson Hall RH-Beamlines RH-ARIEL
  RH-ISAC  Not logged in ELOG logo
Message ID: 426     Entry time: Monday, August 26, 2013, 18:22
Author: Grant Minor 
Category: South Hot-Cell 
Type: Repair 
Module: TM3 
Target/Number:  
Subject: TM3 Rev 3 - all connetions made except steerers, IMG, and entrance window 

Today Chad finished making all connections to the new source tray, except for:

- steerers - broken wire, must be repaired at a later date

- IMG gauge - bracket required, old bracket thrown out with previous tray by accident, see ITA3301, must be installed at a later date

- entrance window - the window lines on module side were left blanked-off for leak checking, containment box must be removed in the next few days to complete steerer repairs so these lines were not connected to save work from having to be repeated

The containment box was replaced, and TM3 was moved to the CS for pump-down and leak checking (see other e-log).  David reported at 6:15 pm that the turbos were turned on at the CS and the vacuum looked normal (so far).

As stated above, Chad realized today that he had thrown out the old IMG gauge bracket with the previous source tray, and a new one must be manufactured.  The assembly is described by ITA3301.  Three components must be manufactured (ITA3302, ITA3303, and ITA2673).  A stock split-ring clamp for ITA2673 (MDC #716001) was graciously donated by Dimo Yosifov.  Grant Minor submitted a work order to the machine shop today for 2 each of ITA3302 and ITA3303.

Attachment 1: TM3_ST_install_before_move_to_CS_26Aug2013.JPG  2.469 MB  | Show | Hide all
Attachment 2: TM3_ST_install_before_move_to_CS_26Aug2013-001.JPG  2.272 MB  | Show | Hide all
Attachment 3: TM3_ST_install_before_move_to_CS_26Aug2013-002.JPG  2.130 MB  | Show | Hide all
Attachment 4: TM3_ST_install_before_move_to_CS_26Aug2013-003.JPG  3.692 MB  | Show | Hide all
Attachment 5: TM3_ST_install_before_move_to_CS_26Aug2013-004.JPG  2.363 MB  | Hide | Hide all
TM3_ST_install_before_move_to_CS_26Aug2013-004.JPG
Attachment 6: TM3_ST_install_before_move_to_CS_26Aug2013-005.JPG  2.530 MB  | Show | Hide all
Attachment 7: TM3_ST_install_before_move_to_CS_26Aug2013-006.JPG  2.211 MB  | Show | Hide all
Attachment 8: TM3_ST_install_before_move_to_CS_26Aug2013-016.JPG  2.286 MB  | Show | Hide all
ELOG V2.9.2-2455