Subject: TM3 Rev 3 - all connetions made except steerers, IMG, and entrance window 

Today Chad finished making all connections to the new source tray, except for:

- steerers - broken wire, must be repaired at a later date

- IMG gauge - bracket required, old bracket thrown out with previous tray by accident, see ITA3301, must be installed at a later date

- entrance window - the window lines on module side were left blanked-off for leak checking, containment box must be removed in the next few days to complete steerer repairs so these lines were not connected to save work from having to be repeated

The containment box was replaced, and TM3 was moved to the CS for pump-down and leak checking (see other e-log).  David reported at 6:15 pm that the turbos were turned on at the CS and the vacuum looked normal (so far).

As stated above, Chad realized today that he had thrown out the old IMG gauge bracket with the previous source tray, and a new one must be manufactured.  The assembly is described by ITA3301.  Three components must be manufactured (ITA3302, ITA3303, and ITA2673).  A stock split-ring clamp for ITA2673 (MDC #716001) was graciously donated by Dimo Yosifov.  Grant Minor submitted a work order to the machine shop today for 2 each of ITA3302 and ITA3303.

Attachment 1: TM3_ST_install_before_move_to_CS_26Aug2013.JPG  2.469 MB  | Show | Show all
Attachment 2: TM3_ST_install_before_move_to_CS_26Aug2013-001.JPG  2.272 MB  | Show | Show all
Attachment 3: TM3_ST_install_before_move_to_CS_26Aug2013-002.JPG  2.130 MB  | Show | Show all
Attachment 4: TM3_ST_install_before_move_to_CS_26Aug2013-003.JPG  3.692 MB  | Show | Show all
Attachment 5: TM3_ST_install_before_move_to_CS_26Aug2013-004.JPG  2.363 MB  | Show | Show all
Attachment 6: TM3_ST_install_before_move_to_CS_26Aug2013-005.JPG  2.530 MB  | Show | Show all
Attachment 7: TM3_ST_install_before_move_to_CS_26Aug2013-006.JPG  2.211 MB  | Show | Show all
Attachment 8: TM3_ST_install_before_move_to_CS_26Aug2013-016.JPG  2.286 MB  | Show | Show all
ELOG V2.9.2-2455