Tuesday, April 23, 2013, 11:19, Bevan Moss, Conditioning Station, Standard Operation, TM3, N/A, HV Test All common  
|
Monday, May 13, 2013, 15:10, Bevan Moss, Conditioning Station, Standard Operation, TM3, N/A, HV Test All common
|
|
Message ID: 313
Entry time: Tuesday, April 23, 2013, 11:19
Reply to this: 342
|
Author: |
Bevan Moss |
Category: |
Conditioning Station |
Type: |
Standard Operation |
Module: |
TM3 |
Target/Number: |
N/A |
Subject: |
HV Test All common |
|
|
A HV test was conducted yesterday on TM3. There was no target and all items were tied to common or ground. The conductivity of the water ranged from 7.1 to 7.5 Mohm. 40kV @ ~600uA without continuous sparking was achieved. The Strip tool was run but something went wrong with the export and the vacuum gauge data is missing. I have attached the file for reference and the pulled data from the achiver (only logs every 300 seconds). RGA scans were taken periodically during the test nothing unexpected was measured but we also do not know what normal looks like. The RGA application is available at http://www.thinksrs.com/downloads/soft.htm. Other items of note include significant sparks disrupts the communication between the computer and the RGA, the PNG1 gauge and its controller, and TP2 local readout screen. |
|
Time TCS:DIC1:RDCOND [Mohm] TCS:BIAS:RDVOL [V] TCS:BIAS:RDCUR [uA] TCS:IG1:RDVAC [T] TCS:PNG1:RDVAC [T] TCS:IG2:RDVAC [T] TCS:IG1S:RDVAC [T] TCS:EL:RDVOL [V] TCS:EL:RDCUR [mA]
04/22/2013 13:24:54.514767 7.3 BadVal BadVal BadVal BadVal BadVal BadVal BadVal BadVal
04/22/2013 13:24:55.514144 7.3 BadVal BadVal BadVal BadVal BadVal BadVal BadVal BadVal
04/22/2013 13:24:56.513959 7.3 BadVal BadVal BadVal BadVal BadVal BadVal BadVal BadVal
04/22/2013 13:24:57.513859 7.3 BadVal BadVal BadVal BadVal BadVal BadVal BadVal BadVal
04/22/2013 13:24:58.513733 7.3 BadVal BadVal BadVal BadVal BadVal BadVal BadVal BadVal
04/22/2013 13:24:59.513611 7.3 BadVal BadVal BadVal BadVal BadVal BadVal BadVal BadVal
04/22/2013 13:25:00.513548 7.3 BadVal BadVal BadVal BadVal BadVal BadVal BadVal BadVal
04/22/2013 13:25:01.513332 7.3 BadVal BadVal BadVal BadVal BadVal BadVal BadVal BadVal
04/22/2013 13:25:02.513198 7.3 BadVal BadVal BadVal BadVal BadVal BadVal BadVal BadVal
04/22/2013 13:25:03.513101 7.3 BadVal BadVal BadVal BadVal BadVal BadVal BadVal BadVal
04/22/2013 13:25:04.512953 7.3 BadVal BadVal BadVal BadVal BadVal BadVal BadVal BadVal
04/22/2013 13:25:05.512845 7.3 BadVal BadVal BadVal BadVal BadVal BadVal BadVal BadVal
04/22/2013 13:25:06.512694 7.3 BadVal BadVal BadVal BadVal BadVal BadVal BadVal BadVal
04/22/2013 13:25:07.512593 7.3 BadVal BadVal BadVal BadVal BadVal BadVal BadVal BadVal
04/22/2013 13:25:08.512476 7.3 BadVal BadVal BadVal BadVal BadVal BadVal BadVal BadVal
04/22/2013 13:25:09.512319 7.3 BadVal BadVal BadVal BadVal BadVal BadVal BadVal BadVal
04/22/2013 13:25:10.513224 7.3 BadVal BadVal BadVal BadVal BadVal BadVal BadVal BadVal
04/22/2013 13:25:11.513065 7.3 BadVal BadVal BadVal BadVal BadVal BadVal BadVal BadVal
04/22/2013 13:25:17.483675 7.3 BadVal BadVal BadVal BadVal BadVal BadVal BadVal BadVal
04/22/2013 13:25:18.483198 7.3 12.58 BadVal BadVal BadVal BadVal BadVal BadVal BadVal
04/22/2013 13:25:19.483074 7.3 12.58 BadVal BadVal BadVal BadVal BadVal BadVal BadVal
04/22/2013 13:25:20.482940 7.3 12.58 BadVal BadVal BadVal BadVal BadVal BadVal BadVal
04/22/2013 13:25:21.482848 7.3 12.58 BadVal BadVal BadVal BadVal BadVal BadVal BadVal
04/22/2013 13:25:22.529120 7.3 11.44 3.05 BadVal BadVal BadVal BadVal BadVal BadVal
04/22/2013 13:25:23.528590 7.3 11.44 3.35 BadVal BadVal BadVal BadVal BadVal BadVal
04/22/2013 13:25:24.528438 7.3 11.44 3.35 BadVal BadVal BadVal BadVal BadVal BadVal
04/22/2013 13:25:25.528305 7.3 11.44 3.35 BadVal BadVal BadVal BadVal BadVal BadVal
04/22/2013 13:25:26.528488 7.3 11.44 3.35 BadVal BadVal BadVal BadVal BadVal BadVal
04/22/2013 13:25:27.529055 7.3 11.44 3.35 BadVal BadVal BadVal BadVal BadVal BadVal
04/22/2013 13:25:28.528932 7.3 11.44 3.35 BadVal BadVal BadVal BadVal BadVal BadVal
04/22/2013 13:25:29.528851 7.3 11.44 3.35 BadVal BadVal BadVal BadVal BadVal BadVal
04/22/2013 13:25:30.528683 7.3 11.44 3.35 BadVal BadVal BadVal BadVal BadVal BadVal
04/22/2013 13:25:31.528587 7.3 13.73 3.35 BadVal BadVal BadVal BadVal BadVal BadVal
04/22/2013 13:25:32.533445 7.3 13.73 3.35 BadVal BadVal BadVal BadVal BadVal BadVal
04/22/2013 13:25:33.533327 7.3 11.44 3.35 BadVal BadVal BadVal BadVal BadVal BadVal
04/22/2013 13:25:34.537373 7.3 11.44 3.35 BadVal BadVal BadVal BadVal BadVal BadVal
04/22/2013 13:25:35.537097 7.3 11.44 3.35 BadVal BadVal BadVal BadVal BadVal BadVal
04/22/2013 13:25:36.537751 7.3 11.44 3.35 BadVal BadVal BadVal BadVal BadVal BadVal
04/22/2013 13:25:37.537820 7.3 11.44 3.35 BadVal BadVal BadVal BadVal BadVal BadVal
04/22/2013 13:25:38.538733 7.3 11.44 3.35 BadVal BadVal BadVal BadVal BadVal BadVal
04/22/2013 13:25:39.538569 7.3 12.58 3.05 BadVal BadVal BadVal BadVal BadVal BadVal
04/22/2013 13:25:40.538418 7.3 12.58 3.05 BadVal BadVal BadVal BadVal BadVal BadVal
04/22/2013 13:25:41.538297 7.3 11.44 3.35 BadVal BadVal BadVal BadVal BadVal BadVal
04/22/2013 13:25:42.538165 7.3 11.44 3.35 0.00 BadVal BadVal BadVal BadVal BadVal
04/22/2013 13:25:43.538047 7.3 11.44 3.05 0.00 BadVal BadVal BadVal BadVal BadVal
04/22/2013 13:25:44.537916 7.3 11.44 3.05 0.00 BadVal BadVal BadVal BadVal BadVal
04/22/2013 13:25:45.538903 7.3 13.73 3.05 0.00 BadVal BadVal BadVal BadVal BadVal
04/22/2013 13:25:46.539694 7.3 13.73 3.05 0.00 BadVal BadVal BadVal BadVal BadVal
04/22/2013 13:25:47.539540 7.3 13.73 3.05 0.00 0.00 BadVal BadVal BadVal BadVal
04/22/2013 13:25:48.539419 7.3 13.73 3.05 0.00 0.00 BadVal BadVal BadVal BadVal
04/22/2013 13:25:49.539292 7.3 11.44 3.35 0.00 0.00 BadVal BadVal BadVal BadVal
04/22/2013 13:25:50.539189 7.3 11.44 3.35 0.00 0.00 BadVal BadVal BadVal BadVal
04/22/2013 13:25:51.540060 7.3 11.44 3.35 0.00 0.00 BadVal BadVal BadVal BadVal
04/22/2013 13:25:52.539908 7.3 11.44 3.35 0.00 0.00 0.00 BadVal BadVal BadVal
04/22/2013 13:25:53.540092 7.3 13.73 3.35 0.00 0.00 0.00 BadVal BadVal BadVal
04/22/2013 13:25:54.539666 7.3 13.73 3.35 0.00 0.00 0.00 BadVal BadVal BadVal
04/22/2013 13:25:55.539575 7.3 11.44 3.35 0.00 0.00 0.00 BadVal BadVal BadVal
04/22/2013 13:25:56.539413 7.3 11.44 3.35 0.00 0.00 0.00 BadVal BadVal BadVal
04/22/2013 13:25:57.539286 7.3 13.73 3.35 0.00 0.00 0.00 0.00 BadVal BadVal
04/22/2013 13:25:58.539153 7.3 13.73 3.35 0.00 0.00 0.00 0.00 BadVal BadVal
04/22/2013 13:25:59.538179 7.3 12.58 3.35 0.00 0.00 0.00 0.00 BadVal BadVal
04/22/2013 13:26:00.538903 7.3 12.58 3.35 0.00 0.00 0.00 0.00 BadVal BadVal
04/22/2013 13:26:01.538871 7.3 11.44 3.35 0.00 0.00 0.00 0.00 BadVal BadVal
04/22/2013 13:26:02.538659 7.3 11.44 3.35 0.00 0.00 0.00 0.00 BadVal BadVal
04/22/2013 13:26:03.538562 7.3 11.44 3.35 0.00 0.00 0.00 0.00 BadVal BadVal
04/22/2013 13:26:04.538446 7.3 11.44 3.35 0.00 0.00 0.00 0.00 BadVal BadVal
04/22/2013 13:26:05.538316 7.3 12.58 3.05 0.00 0.00 0.00 0.00 BadVal BadVal
04/22/2013 13:26:06.538222 7.3 12.58 3.05 0.00 0.00 0.00 0.00 BadVal BadVal
04/22/2013 13:26:07.538075 7.3 13.73 3.35 0.00 0.00 0.00 0.00 BadVal BadVal
04/22/2013 13:26:08.538171 7.3 13.73 3.35 0.00 0.00 0.00 0.00 BadVal BadVal
04/22/2013 13:26:09.537838 7.3 11.44 3.35 0.00 0.00 0.00 0.00 BadVal BadVal
04/22/2013 13:26:10.537655 7.3 11.44 3.35 0.00 0.00 0.00 0.00 BadVal BadVal
04/22/2013 13:26:11.537527 7.3 13.73 3.35 0.00 0.00 0.00 0.00 BadVal BadVal
04/22/2013 13:26:12.537436 7.3 13.73 3.35 0.00 0.00 0.00 0.00 BadVal BadVal
04/22/2013 13:26:13.537268 7.3 11.44 3.35 0.00 0.00 0.00 0.00 BadVal BadVal
04/22/2013 13:26:14.537406 7.3 11.44 3.35 0.00 0.00 0.00 0.00 BadVal BadVal
04/22/2013 13:26:15.639967 7.3 11.44 3.05 0.00 0.00 0.00 0.00 BadVal BadVal
04/22/2013 13:26:16.639887 7.3 12.58 3.35 0.00 0.00 0.00 0.00 BadVal BadVal
04/22/2013 13:26:17.640787 7.3 12.58 3.35 0.00 0.00 0.00 0.00 BadVal BadVal
04/22/2013 13:26:18.640626 7.3 12.58 3.35 0.00 0.00 0.00 0.00 BadVal BadVal
04/22/2013 13:26:19.640619 7.3 12.58 3.35 0.00 0.00 0.00 0.00 BadVal BadVal
04/22/2013 13:26:20.640442 7.3 10.29 3.35 0.00 0.00 0.00 0.00 BadVal BadVal
04/22/2013 13:26:21.640369 7.3 10.29 3.35 0.00 0.00 0.00 0.00 BadVal BadVal
04/22/2013 13:26:22.641183 7.3 12.58 3.35 0.00 0.00 0.00 0.00 BadVal BadVal
04/22/2013 13:26:23.641029 7.3 12.58 3.35 0.00 0.00 0.00 0.00 BadVal BadVal
04/22/2013 13:26:24.640866 7.3 13.73 3.35 0.00 0.00 0.00 0.00 BadVal BadVal
04/22/2013 13:26:25.640747 7.3 13.73 3.35 0.00 0.00 0.00 0.00 BadVal BadVal
04/22/2013 13:26:26.640673 7.3 11.44 3.35 0.00 0.00 0.00 0.00 BadVal BadVal
04/22/2013 13:26:28.178982 7.3 11.44 3.35 0.00 0.00 0.00 0.00 BadVal BadVal
04/22/2013 13:26:29.179353 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 BadVal
04/22/2013 13:26:30.179183 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 BadVal
04/22/2013 13:26:31.179057 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 BadVal
04/22/2013 13:26:32.178947 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 BadVal
04/22/2013 13:26:33.178849 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 BadVal
04/22/2013 13:26:34.178693 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:26:35.178556 7.3 12.58 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:26:36.178472 7.3 12.58 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:26:37.178303 7.3 10.29 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:26:38.178200 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:26:39.178042 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:26:40.177926 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:26:41.177844 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:26:42.177729 7.3 11.44 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:26:43.177629 7.3 11.44 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:26:44.178423 7.3 11.44 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:26:45.178297 7.3 11.44 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:26:46.178170 7.3 13.73 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:26:47.178089 7.3 13.73 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:26:48.177940 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:26:49.177787 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:26:50.177668 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:26:51.177687 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:26:52.177542 7.3 12.58 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:26:53.177297 7.3 12.58 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:26:54.177157 7.3 10.29 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:26:55.177042 7.3 10.29 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:26:56.176917 7.3 13.73 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:26:57.178097 7.3 13.73 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:26:58.177734 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:26:59.177581 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:00.177404 7.3 11.44 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:01.177286 7.3 11.44 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:02.177183 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:03.176688 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:04.666538 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:05.666722 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:06.666638 7.3 13.73 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:07.666465 7.3 12.58 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:08.666344 7.3 12.58 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:09.667231 7.3 12.58 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:10.667092 7.3 12.58 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:11.666959 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:12.667834 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:13.667734 7.3 13.73 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:15.455589 7.3 13.73 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:16.456394 7.3 13.73 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:17.456238 7.3 13.73 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:18.456114 7.3 13.73 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:19.455993 7.3 11.44 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:20.456902 7.3 11.44 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:21.457770 7.3 12.58 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:22.457610 7.3 12.58 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:23.457575 7.3 12.58 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:24.458447 7.3 12.58 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:25.674933 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:26.675079 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:27.675945 7.3 13.73 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:28.676017 7.3 13.73 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:29.838968 7.3 10.29 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:30.839556 7.3 10.29 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:31.840473 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:32.840332 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:33.840185 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:35.391801 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:36.391894 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:37.391731 7.3 12.58 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:38.391621 7.3 12.58 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:39.391692 7.3 13.73 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:40.391384 7.3 13.73 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:41.392220 7.3 13.73 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:42.392106 7.3 13.73 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:43.391978 7.3 13.73 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:44.391852 7.3 13.73 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:45.391725 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:46.392637 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:47.392514 7.3 12.58 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:48.393342 7.3 12.58 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:49.393223 7.3 11.44 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:50.393089 7.3 11.44 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:51.392628 7.3 11.44 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:52.391846 7.3 11.44 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:53.391713 7.3 12.58 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:54.391594 7.3 12.58 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:55.391630 7.3 10.29 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:56.675906 7.3 10.29 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:57.676197 7.3 13.73 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:58.676065 7.3 13.73 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:27:59.677227 7.3 13.73 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:00.676804 7.3 13.73 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:01.677695 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:02.677596 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:03.678503 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:04.678447 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:06.399267 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:07.400070 7.3 12.58 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:08.399885 7.3 12.58 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:09.399809 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:10.399619 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:11.399516 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:13.656395 7.3 12.58 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:14.657070 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:15.657936 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:16.657789 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:17.657670 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:18.657620 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:19.657463 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:20.657285 7.3 11.44 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:21.658248 7.3 11.44 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:22.658068 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:23.657983 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:24.657790 7.3 11.44 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:25.657704 7.3 11.44 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:26.657530 7.3 12.58 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:27.657455 7.3 12.58 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:28.658316 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:29.658187 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:31.671569 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:32.671781 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:33.672687 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:34.672520 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:35.672422 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:36.672317 7.3 13.73 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:37.672165 7.3 13.73 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:38.673107 7.3 12.58 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:39.672891 7.3 12.58 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:40.673766 7.3 11.44 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:41.673690 7.3 11.44 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:42.673544 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:43.674557 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:44.675383 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:45.675156 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:46.676069 7.3 11.44 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:47.675919 7.3 11.44 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:49.380871 7.3 12.58 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:50.380556 7.3 12.58 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:51.380432 7.3 12.58 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:52.380347 7.3 12.58 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:53.380179 7.3 12.58 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:54.380078 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:55.380951 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:56.380800 7.3 13.73 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:57.380707 7.3 13.73 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:58.380548 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:28:59.380422 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:00.380338 7.3 13.73 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:01.380171 7.3 13.73 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:02.381040 7.3 13.73 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:03.380921 7.3 13.73 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:04.380793 7.3 13.73 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:05.380668 7.3 13.73 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:06.380651 7.3 11.44 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:07.380416 7.3 11.44 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:08.381334 7.3 13.73 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:09.381207 7.3 13.73 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:10.382058 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:11.381912 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:12.381849 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:13.382656 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:14.382594 7.3 13.73 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:15.382427 7.3 13.73 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:16.382327 7.3 13.73 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:17.649989 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:18.650082 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:19.650924 7.3 12.58 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:20.650767 7.3 12.58 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:21.650681 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:22.650530 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:23.650713 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:24.651319 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:25.651199 7.3 11.44 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:26.650994 7.3 11.44 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:27.650869 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:28.650773 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:29.651613 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:30.651518 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:31.651394 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:32.651287 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:33.651133 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:34.651100 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:35.650874 7.3 10.29 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:36.650730 7.3 10.29 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:37.650604 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:38.650563 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:39.651352 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:40.651309 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:41.651192 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:42.651973 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:43.651850 7.3 12.58 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:44.651761 7.3 12.58 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:45.651628 7.3 13.73 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:46.719742 7.3 13.73 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:47.719345 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:48.719221 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:49.720162 7.3 12.58 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:50.719968 7.3 12.58 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:51.719843 7.3 13.73 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:52.719718 7.3 13.73 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:53.719634 7.3 12.58 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:54.720478 7.3 12.58 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:55.720383 7.3 13.73 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:56.720276 7.3 13.73 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:57.721104 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:58.720977 7.3 11.44 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:29:59.721860 7.3 11.44 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:30:00.721721 7.3 11.44 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:30:01.721675 7.3 11.44 3.05 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:30:02.722507 7.3 13.73 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:30:03.723371 7.3 13.73 3.35 0.00 0.00 0.00 0.00 5.49 0.01
04/22/2013 13:30:04.724289 7.3 11.44 3.35 0.00 0.00 0.00 0.00 5.49 0.01
... 7200 more lines ...
|
|
|