Logbooks Lab Maintenance Evaporator_1 Evaporator_2 Laser cutter Target Production Test-Stand RH-ISAC RH-Cyclotron RH-Meson Hall RH-Beamlines RH-ARIEL
  RH-ISAC  Not logged in ELOG logo
Message ID: 2618     Entry time: Tuesday, June 18, 2024, 15:16
Author: Adam Newsome 
Category: Crane 
Type: Maintenance 
Module:  
Target/Number:  
Subject: Pail Handling Tool - Annual Inspection 

The pail handling tool which is used to move 5 gallon pails around the target hall was inspected by A. Newsome. The main tool was checked, but not the spare as it is currently in a disassembled and unusable state. The tool appears to be in good, working condition. The following items were checked.

  • Inspect structural integrity of long tube - check for bending, warpage, dents, cracks, rust/corrosion
  • Inspect structural integrity of hook assembly - check for bending, warpage, dents, cracks, rust/corrosion
  • Inspect fasteners - check all fasteners installed as per drawings, fasteners are tight (note: one fastener on crane interface subassembly was loose - all fasteners in these subassembly were tightened as a precautionary measure)
  • Inspect crane interface assembly - check for damage and wear where the tool connects to the crane
  • Check alignment - verify the tool connects to the crane and hangs vertically with no major misalignment (this step was not done - alignment is regularly checked during operations, and there was no concern as the tube was straight)

 Note: these tools are being inspected monthly by D. Wang and F. Song.

Photos can be found in G:\remote handling\Facilities and Projects\ISAC\Pail Handling Tool\Inspections\June 2024

IMPORTANT: the maximum load capacity and lifter tag for the tool are not present. There is a plan in place to affix these two labels in the very near future.

Attachment 1: PXL_20240618_213742257.jpg  605 kB  | Hide | Hide all
PXL_20240618_213742257.jpg
Attachment 2: PXL_20240618_213455575.jpg  556 kB  | Show | Hide all
Attachment 3: PXL_20240618_213626154.jpg  1.345 MB  Uploaded Tuesday, June 18, 2024, 16:17  | Show | Hide all
ELOG V2.9.2-2455