Logbooks Lab Maintenance Evaporator_1 Evaporator_2 Laser cutter Target Production Test-Stand RH-ISAC RH-Cyclotron RH-Meson Hall RH-Beamlines RH-ARIEL
  RH-ISAC  Not logged in ELOG logo
Message ID: 2524     Entry time: Wednesday, January 17, 2024, 20:09
Author: Carla Babcock 
Category: South Hot-Cell 
Type: Standard Operation 
Module:  
Target/Number: Ta#66 
Subject: Ta#66 post irradiation inspection 

On Jan. 9 we did the PIE on Ta#66. Opened the heat shield and removed the EE. The inside of the heat shield was very black with lots of flakes falling off. The target itself looked overheated, and the container looked pretty bad for a Ta target. The outside of the EE looked perfect but after removing it there was a lot of black stuff on the side and we saw that the Re foil was curled up. Jens said during the runtime that he saw something that looked like a wire in the beam path, so maybe this was it.

Attachment 1: 20240109_100926(1).jpg  1.759 MB  Uploaded Tuesday, January 16, 2024, 09:42  | Show | Hide all
Attachment 2: 20240109_101053.jpg  2.155 MB  Uploaded Tuesday, January 16, 2024, 09:45  | Show | Hide all
Attachment 3: 20240109_102409.jpg  2.694 MB  Uploaded Tuesday, January 16, 2024, 09:47  | Show | Hide all