Author: Carla Babcock 
Category: North Hot-Cell 
Type: Standard Operation 
Module: TM4 
Target/Number: SiC#44 
Subject: PIE on SiC#44 

Conducted PIE on SiC#44, which failed online. It had a cathode short, a target short and an anode short by the time we called the experiment off. In the post irradiation examination, two clear marks where the target legs touched the heat shield were found (see attachments 1 and 2). No marks were found to indicate where the cathode short would have been. The fibreglass sheath covering the anode wire where it passes over top of the coil was destroyed, must have been a result of sparking (see attachment 3). No other issues noticed, grid looked fine, though close inspection is difficult.

Attachment 1: SiC44_PIE_20221012_150145.jpg  1.889 MB  | Hide | Hide all
SiC44_PIE_20221012_150145.jpg
Attachment 2: SiC44_PIE_20221012.jpg  1.709 MB  | Show | Hide all
Attachment 3: SiC44_PIE_20221012_161755.jpg  2.246 MB  | Show | Hide all