Logbooks Lab Maintenance Evaporator_1 Evaporator_2 Laser cutter Target Production Test-Stand RH-ISAC RH-Cyclotron RH-Meson Hall RH-Beamlines RH-ARIEL
  RH-ISAC  Not logged in ELOG logo
Message ID: 2372     Entry time: Monday, October 03, 2022, 14:58
Author: Matthew Gareau 
Category: North Hot-Cell 
Type: Repair 
Module: TM4 
Target/Number: SiC#43 and C#4 
Subject: Loose multipin guide pin 

 Today while I was removing the SiC#43 it was noticed that the multipin guide pin was loose.

This made it difficult to remove the target, and the multipin shoulder bolts removal was required.

With the loose pin it was not possible to attach the multipin for the target C#4.

Chad was able to tighten the multipin guide pin enough, however it became obvious that the pin could not be removed when it was attempted.

With the pin tightened, the target C#4 was installed and all checks were good.

It was recommend that once the C#4 target is removed the TM4 will need some repair to remove the multipin guide pin. 

 

Chad - Also it was noted that the guide pin (ITA6453) in question showed signs of plating or heat (see pictures I've added)

Attachment 1: MicrosoftTeams-image.png  199 kB  Uploaded Tuesday, October 04, 2022, 08:08  | Show | Show all
Attachment 2: MicrosoftTeams-image_(1).png  170 kB  Uploaded Tuesday, October 04, 2022, 08:08  | Show | Show all
Attachment 3: MicrosoftTeams-image_(2).png  171 kB  Uploaded Tuesday, October 04, 2022, 08:08  | Show | Show all
ELOG V2.9.2-2455