Message ID: 1790     Entry time: Monday, September 24, 2018, 10:21
Author: Anders Mjos 
Category: South Hot-Cell 
Type: Standard Operation 
Module: TM2 
Target/Number: UC#23 
Subject: Post Irradiation Examination (PIE) 

UC#23 experienced short between target and heat shield as it was heated during operation. The inspection of the target after irradiation revealed that the left target leg was close to the heat shield opening and likely the cause of the short. Marks could be seen on the leg indicating contact. See attached photo. More photos are available on DocuShare

Attachment 1: 20180924_161322929_iOS.jpg  6.224 MB  | Show | Hide all