Logbooks Lab Maintenance Evaporator_1 Evaporator_2 Laser cutter Target Production Test-Stand RH-ISAC RH-Cyclotron RH-Meson Hall RH-Beamlines RH-ARIEL
  RH-ISAC  Not logged in ELOG logo
Message ID: 1704     Entry time: Friday, April 27, 2018, 15:06
Author: Keith C Ng 
Category: ITW 
Type: Repair 
Module:  
Target/Number:  
Subject: ITW beam tube repair 

Vacuumed out remainder of debris from the wall penetration, removed cradle and checked condition. Down stream support bracket sees advanced stages of material loss (OBO 20-30% loss). See attached photos.

RPG reports that the removed beam tube has 15k CPM on the interior of the beam tube.

Tank flange was cleaned as per 2009 repair report, looks OK. Video capture of flange inspection attached as .zip file.

.03" shim was inserted into the clamp indexing block.

 

Attachment 1: 20180427_2a2windowbeamline_P1040042.JPG  5.171 MB  | Show | Hide all
Attachment 2: 20180427_2a2windowbeamline_P1040043.JPG  5.387 MB  | Show | Hide all
Attachment 3: 20180427_2a2windowbeamline_P1040044.JPG  5.216 MB  | Show | Hide all
Attachment 4: 20180427_2a2windowbeamline_P1040046.JPG  5.258 MB  | Hide | Hide all
20180427_2a2windowbeamline_P1040046.JPG
Attachment 5: 20180427_2a2windowbeamline_P1040041.JPG  5.690 MB  | Show | Hide all
Attachment 6: 2018_2a2windowinspection.zip  156 kB
ELOG V2.9.2-2455