Message ID: 1532     Entry time: Wednesday, May 10, 2017, 14:00
Author: Anders Mjos 
Category: South Hot-Cell 
Type: Development 
Module:  
Target/Number: ITE-Ta-LP-FEBIAD 
Subject: Test target examination 

Chad and Anders inspected the test target in the hot cell today. The lid had been previously removed.

  • The EE looked to have performed well. 
  • A piece of Ta foil was found inside the heat shield. It is not clear if this has been there during operation or if it entered the heat shield while in the hot cell. The foil has markings which indicate that it has seen heat.
  • Travis measured 40 MOhm at 500V between heat shield and anode after the target was removed.

Photos are available on DocuShare