Friday, July 13, 2012, 16:33, Bevan Moss, Crane, Repair, , , Crane has stopped working
|
Monday, July 16, 2012, 11:55, Bevan Moss, Crane, Repair, , , Crane has stopped working
|
|
Message ID: 147
Entry time: Monday, July 16, 2012, 11:55
In reply to: 146
|
Author: |
Bevan Moss |
Category: |
Crane |
Type: |
Repair |
Module: |
|
Target/Number: |
|
Subject: |
Crane has stopped working |
|
|
Bevan Moss wrote: |
In the AM today David and I used the crane to raise the ground plate sheet metal into place. This afternoon when I attempted to return the crane to its usual place I discovered that the crane no longer worked. Upon further inspection it appears that the PLC has lost power. I will follow up on this Monday morning. The crane is not supporting any load at this point.
|