Message ID: 1459
Entry time: Thursday, March 23, 2017, 11:22
|
Author: |
Grant Minor |
Category: |
Crane |
Type: |
Maintenance |
Module: |
|
Target/Number: |
|
Subject: |
Target Hall crane 20 ton hoist noise / smell - inspection by Gordon Crane & Hoist |
|
|
Strange noise and a burning brake type smell was observed yesterday by David and Anders when running the main 20 ton hoist locally. A service call was arranged today with Gordon Crane. No major issues were found. A more detailed summary is in the attached e-mail correspondence. Gordon Crane will issue a formal report, but they recommend replacing both sets of brake disks and brake calipers. - Grant |
|
|
|
|