Message ID: 1200     Entry time: Friday, April 08, 2016, 08:13
Author: Anders Mjos 
Category: ITE/ITW Cooling 
Type: Maintenance 
Module:  
Target/Number:  
Subject: High Active Water Resistivity 

The high active water resistivity took a long time to recover after the upgrade to the water cooling circuit. The system needed about a month (from end February to end March) to recover to nominal values. See attached plot of archiver data.

TM1 has now been connected in ITW and the water resistivity remains > 8 MOhm cm, which should allow normal operation. However, the resin is suspected to be approaching end of life. Work is ongoing to get a new replacement resin tank.

Attachment 1: 2016-04-08_ISAC_High_Active_Water_Resistivity.png  17 kB  | Show | Hide all