Logbooks
Lab Maintenance
Evaporator_1
Evaporator_2
Laser cutter
Target Production
Test-Stand
RH-ISAC
RH-Cyclotron
RH-Meson Hall
RH-Beamlines
RH-ARIEL
|
RH-ISAC |
Not logged in |
|
|
Message ID: 101
Entry time: Tuesday, May 15, 2012, 12:14
|
Author: |
chad fisher |
Category: |
South Hot-Cell |
Type: |
Standard Operation |
Module: |
TM4 |
Target/Number: |
SiC#26 |
Subject: |
SiC#26 removal TM4 degredation |
|
|
SiC#26 was removed from target module #4 this morning. Target shows the now standard arc marks on the 9 pin connector housing...pictures to follow.
Of greater concern is the amount of "plating out" or "arc" marks on both the insulators and connductor of the TM4 source tray. I will again warn that the source trays historically have a life expectancy, and that TM4 continues to show visual signs that the current source tray is rapidly approaching the end of its useful life!
I understand that one of this years goals is to retrofit TM3; however I fear TM4(and possibly TM1) may fail before this can be released. With the current absence of backup source trays and modules I fear we leave the ISAC program in a very vulnerable position.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|