Logbooks Lab Maintenance Evaporator_1 Evaporator_2 Laser cutter Target Production Test-Stand RH-ISAC RH-Cyclotron RH-Meson Hall RH-Beamlines RH-ARIEL
  RH-Cyclotron  Not logged in ELOG logo
Message ID: 9     Entry time: Monday, February 04, 2013, 13:52
Author: Grant Minor 
Category: Service Bridge 
Type: Repair 
Subject: Hydraulic cylinder failure on service bridge 

The hydraulic cylinder on the West side of the service bridge (used to raise the bridge for insertion into the Cyclotron) failed this morning, leaking oil in the vault tunnel.  Most likely this was due to a failed seal or gasket.

Maico Dalla Valle has removed both the East and West cylinders for refurbishment and is pursuing repair kits from Hyseco.

The purple coloured cylinder on the East side has been slowly leaking oil for some time.  A gasket in the West cylinder (yellow) seems to have failed and a broken piece of the gasket was removed during the disassembly, shown in the photo "Hydraulic Cylinder Gasket 4 Feb 2013 008.jpg" attached.

Cylinder model number is ENERPAC RC-254.

http://www.hyseco.com/

 

Attachment 1: Hydraulic_Cylinder_Gasket_4_Feb_2013_001.jpg  860 kB  | Show | Hide all
Attachment 2: Hydraulic_Cylinder_Gasket_4_Feb_2013_002.jpg  825 kB  | Show | Hide all
Attachment 3: Hydraulic_Cylinder_Gasket_4_Feb_2013_004.jpg  712 kB  | Show | Hide all
Attachment 4: Hydraulic_Cylinder_Gasket_4_Feb_2013_005.jpg  758 kB  | Show | Hide all
Attachment 5: Hydraulic_Cylinder_Gasket_4_Feb_2013_008.jpg  687 kB  | Show | Hide all
Attachment 6: Hydraulic_Cylinder_Gasket_4_Feb_2013_010.jpg  825 kB  | Hide | Hide all
Hydraulic_Cylinder_Gasket_4_Feb_2013_010.jpg
ELOG V2.9.2-2455