Logbooks Lab Maintenance Evaporator_1 Evaporator_2 Laser cutter Target Production Test-Stand RH-ISAC RH-Cyclotron RH-Meson Hall RH-Beamlines RH-ARIEL
  RH-Cyclotron  Not logged in ELOG logo
Message ID: 72     Entry time: Wednesday, September 30, 2015, 11:52
Author: Isaac Earle 
Category: Elevation Jack 
Type: Standard Operation 
Subject: Station 9 Jack Left Side - Inspection & Service Status 

The left side jack was disassembled and cleaned.  It was discovered that the left side had been rebuilt with a new jack nut (similar to the three spare jack nuts in the RH machine shop).  This nut had been machined as is required to fit the bearing races on and fit the nut into the jack nut case.  The jacking case and lid also were machined to accommodate the different size rings for both ends of the nut  This rebuild may have been done after the jack failure that occurred in the late 70s / early 80s due to incorrect bearings and grease in the jacks.

There was less grease in the left side, and one of the worm bearings was on the dry side.  All other components still seemed lubricated, but not as much as the right side.  It seemed that some grease was stuck on the outsides of the jacking case and not mixing with the other grease.  The jacking case was approximately 70% full of grease.

There was a normal amount of wear visible on the surfaces of all jack parts according to Maico.  No unusual wear or colouration such as on the right side observed.  A leak in the shaft seal opposite the drive coupling was observed - this was replaced upon reassembly.

 

The jack was reassembled without grease .  The following measurements were taken:
Nut in jack case - vertical play:  0.008"  (vertical when installed)
Nut in jack case - tilt:  0.008"
Worm gear backlash:  0.017"

Nut on jack screw - backlash:  0.040"
Nut on jack screw - horizontal play on top of nut:  0.031"
Nut on jack screw - horizontal play on bottom of nut:  0.031"

 

The left side jack was fully reassembled with grease and is ready for installation.
 

Attachment 1: IMG_2059.JPG  632 kB  | Show | Hide all
Attachment 2: IMG_2060.JPG  508 kB  | Show | Hide all
Attachment 3: IMG_2062.JPG  484 kB  | Show | Hide all
Attachment 4: IMG_2063.JPG  516 kB  | Show | Hide all
Attachment 5: IMG_2064.JPG  434 kB  | Show | Hide all
Attachment 6: IMG_2065.JPG  443 kB  | Hide | Hide all
IMG_2065.JPG
Attachment 7: IMG_2066.JPG  468 kB  | Show | Hide all
Attachment 8: IMG_2067.JPG  581 kB  | Show | Hide all
Attachment 9: IMG_2068.JPG  407 kB  | Show | Hide all
Attachment 10: IMG_2069.JPG  578 kB  | Show | Hide all
Attachment 11: IMG_2071.JPG  411 kB  | Show | Hide all
Attachment 12: IMG_2072.JPG  592 kB  | Show | Hide all
Attachment 13: IMG_2073.JPG  542 kB  | Show | Hide all
Attachment 14: IMG_2074.JPG  588 kB  | Show | Hide all
Attachment 15: IMG_2075.JPG  628 kB  | Show | Hide all
ELOG V2.9.2-2455