Message ID: 70     Entry time: Thursday, September 17, 2015, 18:38
Author: Grant Minor 
Category: Elevation Jack 
Type: Maintenance 
Subject: Station 9 Jack Worm Gear Inspection - unusual wear markings 16Sept2015 

Unusual wear markings were observed on the Station 9 jack (not sure if L or R jack?) during a visual inspection.

The grease looked to be in good condition and no sign of chips or contamination was found in the grease, so it is possible that the wear markings are older.

More investigation is required before using this worm gear assembly again.

Grant Minor, P.Eng.

 

Attachment 1: Station_9_Worm_Gear_Spur_Spline_Wear_16Sept2015.JPG  2.035 MB  | Show | Hide all
Attachment 2: Station_9_Worm_Gear_Spur_Spline_wear_2_16Sept2015.JPG  2.125 MB  | Show | Hide all
Attachment 3: Station_9_worm_gear_wear_markings_2_16Sept2015.JPG  2.044 MB  | Show | Hide all
Attachment 4: Station_9_worm_gear_wear_markings_3_16Sept2015.JPG  2.002 MB  | Show | Hide all
Attachment 5: Station_9_worm_gear_wear_markings_16Sept2015.JPG  1.960 MB  | Show | Hide all
Attachment 6: New_Worm_Gear_Spur_Spline_for_comparison_16Sept2015.JPG  2.101 MB  | Show | Hide all
Attachment 7: Station_9_jack_bearing_races_16Sept2015.JPG  2.328 MB  | Hide | Hide all
Station_9_jack_bearing_races_16Sept2015.JPG
Attachment 8: Station_9_jack_bearing_races_2_16Sept2015.JPG  2.444 MB  | Show | Hide all