Logbooks Lab Maintenance Evaporator_1 Evaporator_2 Laser cutter Target Production Test-Stand RH-ISAC RH-Cyclotron RH-Meson Hall RH-Beamlines RH-ARIEL
  RH-Beamlines  Not logged in ELOG logo
Message ID: 92     Entry time: Wednesday, March 16, 2016, 17:57
Author: Ron Kuramoto 
Category: Primary Beamlines 
Type: Development 
Subject: 4VQ1&Q2 Removal 

 On 14March2016, 4VQ1&Q2 were removed from BL4V and lowered into the Vault basement B3 level where they were stored in the south west corner on their respective wood pallets.  The hot ends of both magnets were place against the west wall.  4VQ2 was lifted out first and moved temporarily downstream where it was separated from its magnet stand. Q2 was then craned into the basement where it was tipped 45o to lay on the flat side of the magnet face.  Q2’s magnet  stand and it’s mounting brackets were then craned down onto another pallet and moved to the same storage area.

4VQ1 was pulled about 3-4 ft. downstream using a pair of ¾ Ton come-along winches to clear the overhead Elevating Jacks platform.   Q1 was then separated from its stand where both were lowered onto pallets like Q2 and moved to the storage area.  Four concrete shield blocks were postioned down stream of 4VCM1 to shield the beam exit port.

The total accumulated dose received was 0.46mSv spread amongst 5 people.  See W/P C2016-03-11-5 for Rad survey levels of Q1 & Q2.

See the attached photos.

Attachment 1: IMG_1928.JPG  3.524 MB  | Hide | Hide all
IMG_1928.JPG
Attachment 2: IMG_1934.JPG  3.033 MB  | Show | Hide all
Attachment 3: IMG_1935.JPG  2.996 MB  | Show | Hide all
Attachment 4: IMG_1937.JPG  3.420 MB  | Show | Hide all
Attachment 5: IMG_1943.JPG  3.278 MB  | Show | Hide all
Attachment 6: IMG_1945.JPG  3.428 MB  | Show | Hide all
Attachment 7: IMG_1946.JPG  3.443 MB  | Show | Hide all
Attachment 8: IMG_1948.JPG  3.339 MB  | Show | Hide all
Attachment 9: IMG_1951.JPG  3.011 MB  | Show | Hide all
Attachment 10: IMG_1954.JPG  3.114 MB  | Show | Hide all
Attachment 11: IMG_1957.JPG  3.476 MB  | Show | Hide all
Attachment 12: IMG_1961a.jpg  2.612 MB  | Show | Hide all
Attachment 13: IMG_1968.JPG  3.377 MB  | Show | Hide all
ELOG V2.9.2-2455