Message ID: 119
Entry time: Tuesday, April 16, 2019, 11:19
|
Author: |
Ron Kuramoto |
Category: |
Primary Beamlines |
Type: |
Repair |
Subject: |
1AQ14 B/L Flange Broken Thermocouple |
|
|
On March 7,2019 the Thermocouple (TC) cable which monitors the temperature of the 1AQ14 B/L vacuum joint was broken when the iron shield block (Triumf Dwg D-3237 aka M8 Tongue block) was restored on the east of the T2 Monolyth. See attached photos. This TC (Omega #KTSS-116U-144) is attached to the 1AQ14 Indium ring seal (Triumf Ref Dwg TBP0372D) and should be replaced the next time this B/L joint is serviced.
The Controls Group has noted on the CCSC2, XTPAGE 17, that TW# B1-375 is broken. |
|
|
|
|