Logbooks Lab Maintenance Evaporator_1 Evaporator_2 Laser cutter Target Production Test-Stand RH-ISAC RH-Cyclotron RH-Meson Hall RH-Beamlines RH-ARIEL
  RH-Beamlines  Not logged in ELOG logo
Message ID: 117     Entry time: Tuesday, March 27, 2018, 15:08
Author: Keith C Ng 
Category: M9 
Type: Standard Operation 
Subject: t2 m9 port blank off 

1. Blank off installed 11:40 with Dan McDonald, east spring ear looks 'deeper" than west.

- Reused all hardware from last install, most active hardware was around 10 mSv/h on contact

- Zero point was at the 1/2 turn marker pen mark

- Installed at 1.5 turns from "finger tight" zero.

 

2. Spring eye zero set on a spare flange with spare pins.

- backed off 1/2 turn then mounted to exit port.

- tightened .5 turn to get to zero, then 1.5 turns on east and west sides to seal, in increments of .5 turns alternating.

 

3. Called Edi to start pumping on T2 at 12:50

Attachment 1: 20180327_t2m9_P1030978.JPG  5.292 MB  | Hide | Hide all
20180327_t2m9_P1030978.JPG
Attachment 2: 20180327_t2m9_P1030979.JPG  5.272 MB  | Show | Hide all
ELOG V2.9.2-2455